Nov 19, 2026·Pranesh Mahanta·21ECC205T — Electromagnetic Theory and Interference
Quarter-wave transformer, the Smith chart and single-stub matching — the complete unit, with every worked question stated in full and solved step by step.
Impedance matching is designing the source and load impedances so as to minimize signal
reflection, or to maximize power transfer, between a line and its termination. When
ZL ≠ Z0 the load is mismatched and a reflected wave exists on the
line. The reflections superpose on the incident wave, producing constructive and destructive
interference — peaks and valleys in the voltage along the line — and the power
that should reach the load bounces back toward the source.
For maximum power transfer the load must be matched to the line, ZL =
Z0, so that there is no reflection: |Γ| = 0 and the standing-wave ratio s = 1.
Matching therefore buys a desirable VSWR (ideally 1), no wasted power, and no hot spots on
the line.
Matching networks are the configurations used to match source and load impedances; the
impedance matching devices are the components that make up those networks. Finding the
component values can be done by computer simulation, manual computation, or — the classic
route and the subject of this unit — graphically, with the Smith chart.
2Matching devices & the quarter-wave transformer
The common matching devices, all built from short sections of transmission line:
λ/4 line — the quarter-wave transformer
λ/2 line
λ/8 line
Single-stub matching
Double-stub matching
Quarter-wave transformer
Take a lossless line of characteristic impedance Z0 terminated in ZL.
Its input impedance at length l:
choose l = λ/4 ⇒ βl = (2π/λ)(λ/4) = π/2, tanβl → ∞; divide numerator and denominator by tanβl and only the j-terms survive.
l = λ/4: Zin = Z0 (jZ0)/(jZL) = Z0²/ZL
the quarter-wave section inverts the load: high ↔ low. Placed between two resistive levels it matches them when its own characteristic impedance is the geometric mean, Z′0 = √(Z0ZL).
Quarter-wave transformer: a λ/4 section of impedance Z′0 = √(Z0ZL) matches the load to the line.
Worked problem · quarter-wave design
Design a transmission line segment that matches 300 Ω to 50 Ω at 10 GHz using a quarter-wave match.
Setup. Main line Z0 = 50 Ω, load ZL = 300 Ω, f = 10 GHz, air line so u = c = 3×10⁸ m/s. The λ/4 section sits between them with characteristic impedance Z′0 and length l — the two unknowns. Step 1 — input impedance of a lossless line at length l:
Answer. A λ/4 section of Z′0 = 122.5 Ω, l = 7.5 mm long, matches the 300 Ω load to the 50 Ω line: the 300 Ω load now looks like 50 Ω to the main line.
Other fixed lengths. A λ/2 section has βl = π, tanβl = 0 ⇒ Zin = ZL: it repeats the load unchanged at its input. A λ/8 section (βl = π/4) is the shortest section with a useful impedance-transforming ratio and appears in the same family of designs.
3The Smith chart — construction and key points
The Smith chart is a polar graph of the normalized impedance in the complex
reflection-coefficient plane. If Z = R + jX is the impedance at some location along a lossless
line, each point of the chart is the intersection of an R−X circle pair — the
loci of constant normalized resistance R and constant normalized reactance X, both drawn as
circles inside the |Γ| = 1 boundary.
The Smith chart: constant-R and constant-X circles inside the |Γ| = 1 rim. Every normalized impedance (R + jX) sits at the intersection of one circle of each family.
Key points
Explain the construction of the Smith chart and its key points.
Setup. A lossless line of characteristic impedance Z0; at a point on it the impedance is Z = R + jX and the reflection coefficient is K. The chart is drawn in the complex K plane, so every quantity below is a point or a circle in that plane. Step 1 — the mapping that draws the chart:
K = (Z − Z0)/(Z + Z0) = (z − 1)/(z + 1), z = Z/Z0 …(1)
z = R + jX in (1) ⇒ constant-R and constant-X loci are circles inside the |K| = 1 rim …(2)
Step 2 — the prime centre:
z = 1 + j0 ⇒ K = (1 − 1)/(1 + 1) = 0 …(3)
K = 0 ⇒ s = (1 + |K|)/(1 − |K|) = 1/1 = 1 …(4)
Step 3 — normalization:
z = Z/Z0 …(5) y = Y/Y0 = 1/z …(6)
one chart in z therefore serves every line, whatever its Z0
Step 4 — the real axis and the rim:
K = +1 (right end): z = (1 + 1)/(1 − 1) → ∞, open circuit …(7)
K = −1 (left end): z = (1 − 1)/(1 + 1) = 0, short circuit …(8)
rim |K| = 1; the rim scale reads wavelengths toward generator (WTG), one full turn = 0.5λ …(9)
Step 5 — the SWR circle and its two real-axis crossings:
right crossing: z = s = Vmax/Vmin …(10)
left crossing: z = 1/s …(11)
Answer. A polar graph of normalized impedance in the complex reflection-coefficient plane: the normalized impedance z = R + jX is read at the intersection of the R- and X-circle pair, the centre is 1 + j0 (ZR = Z0, K = 0, s = 1 — a smooth, flat line), the right end of the real axis is open circuit and the left end short circuit, and the SWR circle's real-axis crossings give Vmax (z = s) and Vmin (z = 1/s).
4Applications & reading the chart
Applications of the Smith chart:
find the input impedance and input admittance of the line;
measure the input impedance and load impedance;
measure the standing-wave ratio (SWR);
measure the reflection coefficient K in polar form;
locate the voltage minimum and maximum; and, in single-stub matching, find the
distance of the stub from the load and the length of the stub.
The standard moves. Plot the normalized load zL = ZL/Z0.
With centre O draw the SWR circle through it: where it cuts the real axis to the
right of centre, that reading is the SWR (s), because that point is Vmax where
z = Vmax/Vmin. The reflection coefficient follows from the same circle:
|K| = (s − 1)/(s + 1) angle ∅: from the load's position on the WTG scale K = |K| ∠∅
input impedance at distance l: rotate from the load point toward the generator by l/λ (clockwise on the WTG scale) along the SWR circle and read the z there; the input admittance is the point diametrically opposite (or 0.25λ away) — the quarter-wave inverter again.
Where |K| = (s − 1)/(s + 1) comes from. At Vmax the incident and reflected waves add in phase, at Vmin they oppose:
Vmax = |V+|(1 + |K|) …(1) Vmin = |V+|(1 − |K|) …(2)
s = Vmax/Vmin = (1 + |K|)/(1 − |K|) …(3)
s(1 − |K|) = 1 + |K| ⇒ s − 1 = |K|(s + 1) ⇒ |K| = (s − 1)/(s + 1) …(4)
5Problem 1 · 30-m line — K, SWR, input impedance
Worked problem · full chart procedure
A 30-m-long lossless transmission line with Z0 = 50 Ω operating at 2 MHz is terminated with a load ZL = 60 + j40 Ω. If u = 0.6c on the line, find (a) the reflection coefficient, (b) the standing-wave ratio, and (c) the input impedance.
Setup. Z0 = 50 Ω, ZL = 60 + j40 Ω, l = 30 m, f = 2 MHz, u = 0.6c = 0.6 × 3×10⁸ = 1.8×10⁸ m/s. Unknowns: K, s, Zin. Step 1 — normalize the load and plot it:
zL = ZL/Z0 = (60 + j40)/50 = 60/50 + j40/50 = 1.2 + j0.8 …(1)
mark the intersection of the R = 1.2 circle with the +j0.8 circle
Step 2 — draw the SWR circle:
centre O = 1 + j0, radius O–zL; the circle cuts the real axis right of centre at s = 2.1 …(2)
A section of transmission line of small length is a stub. A single stub: a
two-wire line section of small length lstub connected in parallel with the main
line, at a distance dstub from the load. Two design parameters fix the match:
The location of the stub with reference to the load, dstubthe length of the stub line, lstub
the stub line is terminated in a short or an open circuit; its input admittance is always purely imaginary — inductive if negative, capacitive if positive: Ystub = jBstub.
Single-stub matching: a shunt stub at distance dstub from the load cancels the line's susceptance there.
For a proper match: Y(dstub) = Y0 + jB(dstub) and Bstub = −B(dstub) ⇒ Ystub + Y(dstub) = Y0
so the stub must sit where the line admittance has real part exactly Y₀ — on the g = 1 circle of the admittance (mirrored) chart. Depending on line length there can be several admissible locations; the point near the load is usually taken, and it lies close to a voltage minimum Vₐₔ, where the admittance is largest.
Short or open stub? A short-circuited stub is less prone to leakage of electromagnetic radiation and is somewhat easier to realize. An open-circuited stub may be more practical for lines like microstrip, where shorting the two conductors would mean drilling the insulating substrate.
7Problem 2 · stub match, 40 + j30 Ω on a 100-Ω line
Worked problem · five-step chart procedure
An antenna with impedance ZL = 40 + j30 Ω is to be matched to a 100-Ω lossless line with a shorted stub. Determine (i) the normalized admittance, (ii) the standing-wave ratio, (iii) the distance of the stub from the load, (iv) the required stub admittance, and (v) the length of the stub.
yL = 1/zL = 100/(40 + j30) = 100(40 − j30)/[(40)² + (30)²] …(2)
(40)² + (30)² = 1600 + 900 = 2500 …(3)
yL = (4000 − j3000)/2500 = 1.6 − j1.2 …(4)
same point by travelling 0.25λ from zL on the chart — the λ/4 inverter
Step 3 — draw the SWR circle:
centre O, radius O–yL; the crossing right of centre gives s = 2.7 …(5)
Step 4 — locate the stub on the g = 1 circle:
the g = 1 circle is the locus of admissible stub points; it cuts the s = 2.7 circle at two points — take point B, the one nearer the load as we move toward the generator (the stub always sits close to a voltage minimum Vmin) …(6)
load on the WTG scale: 0.304λ …(7) point B: 0.336λ …(8)
dstub = 0.336 − 0.304 = 0.032λ …(9)
Step 5 — the susceptance the stub must supply:
at B the line admittance is y = 1 − j1.04, so Bline = −j1.04 (inductive) …(10)
match needs Bstub = −Bline = +j1.04 (capacitive) …(11)
Answer.yL = 1.6 − j1.2, s = 2.7, dstub = 0.032λ, Bstub = +j1.04, lstub = 0.378λ.✓ (exact algebra: d = 0.0325λ, y(d) = 1 − j1.06, l = 0.378λ — the chart reads are right on it.)
Problem 2 on the chart: the SWR circle meets the g = 1 circle at the stub location; the stub arc from the short-circuit point gives its length.
8Problem 3 · stub match, 25 − j50 Ω on a 50-Ω line
Worked problem · both stub solutions
A 50-Ω transmission line is connected to a cellular-phone antenna with load impedance ZL = 25 − j50 Ω. Use the Smith chart to find the position and the length of a shunt short-circuited stub required to match the 50-Ω line.
Answer. Either d = 0.063λ with a 0.09λ inductive shorted stub (preferred — both lengths shorter), or d = 0.207λ with a 0.41λ capacitive stub. Both leave a normalized junction admittance of exactly 1 + j0: matched.
9Problem 4 · both stub solutions for zL = 0.4 − j0.4
Worked problem · single parallel stub tuner
Use a single parallel stub tuner to match the 50-Ω line to its load zL = 0.4 − j0.4. Use a shorted stub and find its distance from the load, ℓ1, and its length ℓ2.
Setup. Z0 = 50 Ω, zL = 0.4 − j0.4 (already normalized), short-circuited shunt stub. Unknowns: ℓ1 (stub distance from the load) and ℓ2 (stub length). Step 1 — load admittance by inversion:
stub is lossless ⇒ y2 = jb (purely susceptive) …(5)
parallel junction must present unit normalized admittance: y1 + y2 = 1.0 …(6)
⇒ y1 = 1.0 − jb — the unit conductance circle …(7)
Step 3 — first solution, the intersection:
rotate from yL toward the generator until the SWR circle meets g = 1: y1 = 1.0 − j1.15 …(8)
y2 = 1.0 − y1 = +j1.15 …(9)
Step 4 — distance of the stub from the load:
yL at 0.181λ on the WTG scale …(10) y1 at 0.334λ …(11)
ℓ1 = 0.334 − 0.181 = 0.153λ …(12)
Step 5 — length of the stub:
yshort = −j cotβℓ2 = +j1.15 ⇒ cotβℓ2 = −1.15 …(13)
βℓ2 = π − tan⁻¹(1/1.15) = 3.1416 − 0.7155 = 2.4261 rad …(14)
ℓ2/λ = 2.4261/2π = 0.386λ …(15)
chart route, same answer: 0.25λ on the wavelengths-toward-load scale + 0.136λ on the wavelengths-toward-generator scale = 0.386λ (the arc from the short wraps past the 0.5λ/0λ rim point, so the two stretches are read on the two scales)
Step 6 — second solution:
rotating past the first intersection meets g = 1 again at y1 = 1.0 + j1.15 …(16)
y2 = 1.0 − y1 = −j1.15 …(17)
y1 at 0.334 + 0.5 = 0.666λ ⇒ ℓ1 = 0.666 − 0.181 = 0.485λ …(18)
cotβℓ2 = +1.15 ⇒ βℓ2 = 0.7155 rad ⇒ ℓ2/λ = 0.7155/2π = 0.114λ …(19)
Answer. ℓ1 = 0.153λ with ℓ2 = 0.386λ (or the second solution ℓ1 = 0.485λ with ℓ2 = 0.114λ). When one solution makes both sections shorter it normally has the greater bandwidth; here the two trade off against each other.
10Problem 5 · 5 + j25 Ω load, line 0.1λ long
Worked problem · SWR, K and input impedance
An air-filled two-wire line has a characteristic impedance of 50 Ω and is terminated with a load impedance of 5 + j25 Ω. The length of the line is 0.1λ. Find (i) the standing-wave ratio, (ii) the reflection coefficient, and (iii) the input impedance.
11Problem 6 · 100 + j40 Ω at 3 GHz, impedance at 2.5 cm
Worked problem · VSWR and line impedance
An air-filled two-wire line has a characteristic impedance of 50 Ω and is operated at f = 3 GHz. The load is ZL = 100 + j40 Ω. Find the VSWR and the line impedance at 2.5 cm from the load.
Setup. Z0 = 50 Ω, ZL = 100 + j40 Ω, f = 3 GHz, air-filled line, distance from the load 2.5 cm. Unknowns: VSWR and Zin. Step 1 — normalize the load:
zL = ZL/Z0 = (100 + j40)/50 = 100/50 + j40/50 = 2 + j0.8 …(1)
upper-right region of the chart
Step 2 — VSWR:
the SWR circle through zL cuts the real axis right of centre at s = 2.4 …(2)
Step 3 — reflection coefficient of the load:
|K| = (s − 1)/(s + 1) = (2.4 − 1)/(2.4 + 1) = 1.4/3.4 = 0.41 …(3)
angle read on the rim: ∅ = 23.7° …(4)
Step 4 — wavelength on the air line:
λ = c/f = 3×10⁸/(3×10⁹) = 0.1 m = 10 cm …(5)
Step 5 — the distance in wavelengths:
2.5 cm/10 cm = 0.25λ …(6)
exactly a quarter wavelength — half a full turn on the chart
Step 6 — quarter-wave inversion:
rotating 0.25λ toward the generator lands diametrically opposite zL, i.e. on the normalized admittance of the load …(7)
zin = 1/zL = 1/(2 + j0.8) = (2 − j0.8)/[(2)² + (0.8)²] …(8)
(2)² + (0.8)² = 4 + 0.64 = 4.64 …(9)
zin = (2 − j0.8)/4.64 = 0.431 − j0.172 ≈ 0.43 − j0.17 …(10)
Answer.VSWR = 2.4, Zin = 21.6 − j8.6 Ω✓ — the high resistive load is inverted into a low resistive input, exactly what a λ/4 section does.
12Companion tool — Smith chart calculator
I built an interactive companion to this unit while working through it — it plots z and y,
draws the SWR and g = 1 circles, and solves the stub problem numerically so the chart answers can
be checked in seconds: