EMT Notes: Transmission Lines, EMI & EMC

Nov 19, 2026·Pranesh Mahanta·21ECC205T — Electromagnetic Theory and Interference

Transmission lines from the telegrapher's equations to the LISN, plus the EMI/EMC toolkit — the complete unit, with every worked question stated in full and solved step by step.

Contents
  1. Transmission lines — what and why
  2. Primary constants R, L, G, C
  3. Telegrapher's equations → wave solutions
  4. α, β, λ, vₖ, Z₀ — meaning + numbers
  5. Lossless, distortionless, low-loss
  6. Input impedance Zₖₙ
  7. Reflection coefficient, SWR, return loss, power
  8. Short, open, matched + λ/8, λ/4, λ/2 lines
  9. Big line problems (100 km line, cable loading)
  10. EMI vs EMC, classification, sources
  11. Source–path–victim + coupling mechanisms
  12. Conducted vs radiated, emission & immunity, the 4 tests
  13. Conducted emission, CM/DM currents, the LISN
  14. Grounding, shielding, filtering
  15. Shielding effectiveness — skin depth, A, R, M
  16. Formula sheet — everything on one screen

1Transmission lines — what and why

Unguided vs guided. A uniform plane wave in an unbounded medium is unguided — the EM energy spreads over the whole space, which is exactly what radio/TV broadcasting wants. To deliver power or information efficiently from a source to a chosen load we instead use guided structures — transmission lines and waveguides — which direct the energy along a defined path. Transmission lines carry power distribution at low frequencies and signals in communications at high frequencies; twisted-pair and coax are the backbones of Ethernet and other computer networks.

Definition. A transmission line is two or more parallel conductors used to connect a source (generator, transmitter, oscillator) to a load (antenna, factory, oscilloscope). The three classic examples are the coaxial cable (lab instruments, TV down-leads), the two-wire line (open-wire or twisted pair) and the microstrip line (metal strips on a dielectric substrate — the wiring of every PCB and integrated circuit). We analyse lines with circuit theory (easier than full field theory) precisely because a TEM wave lets us replace fields E, H by voltage and current.

coaxialtwo-wiremicrostripa (inner)b (outer)dielectric εd+V−Vopen-wire / twisted pairwhdielectric εstrip (IC wiring)every line = two parallel conductors joining a source to a load
Cross-sections of the three classic lines. Credit: redrawn (after Sadiku fig. 11.1).

The TEM wave on a line. Close the switch of a coax feeding a load: the inner conductor goes positive with respect to the outer one, so E points radially outward; by Ampère's law the current is encircled by H. The Poynting vector S = E × H points along the line — so the disturbance travels as a transverse electromagnetic (TEM) wave (E ⊥ H ⊥ direction of travel; it is a nonuniform plane wave). Two TEM properties do all the work in this unit: V is uniquely related to E and I to H, so circuit quantities replace field quantities.

(a) source connected through a coaxV₀RₗIcoaxial lineE radial (inner → outer)(b) cross-section: E, H fields⊛IEHS = E × H (along line)close switch → inner conductor + w.r.t. outer: E radial outward (Ampère: H encircles current)S = E × H points along the line → a TEM wave carries the power: V ↔ E, I ↔ HTEM = E ⊥ H ⊥ propagation direction (nonuniform plane wave)
(a) Generator–coax–load circuit; (b) cross-section showing radial E, circumferential H and S along the line. Credit: redrawn (after Sadiku fig. 11.4).
V = −∫ E · dℓ     I = ∧ H · dℓ     (TEM line: fields ↔ circuit quantities)
This unique V↔E, I↔H mapping is why the whole unit can be done with R, L, G, C instead of Maxwell's equations.

2Primary constants R, L, G, C

The four line parameters. A line is described by four quantities defined per unit length: R — resistance of the two conductors (Ω/m, series loss in copper); L — inductance (H/m, from flux linkage between the conductors); G — conductance (S/m, leakage through the dielectric); C — capacitance (F/m, charge storage between the conductors). These are the primary constants; γ, Z₀, α, β derived from them are the secondary constants.

Worked problem · The four primary constants
Define the four primary constants (R, L, G, C) of a transmission line and state the unit of each.
Setup — the line is described per unit length, so each primary constant is a rate, not a lump.
R = series resistance of both conductors per metre → Ω/m …(1)
L = series inductance per metre → H/m …(2)
G = shunt (dielectric leakage) conductance per metre → S/m …(3)
C = shunt capacitance per metre → F/m …(4)
Step 1 — dimensional check of Z₀:
Z₀ = √(L/C) → √[(H/m) ÷ (F/m)] = √(H/F) = √[(Ω·s)/(s·Ω⁻¹)] = √(Ω²) = Ω …(5)
Step 2 — dimensional check of γ:
γ = √[(R + jωL)(G + jωC)] → √[(Ω/m)(S/m)] = √(1/m²) = 1/m …(6)
Step 3 — result:
All four are distributed quantities (per metre), so the line is a chain of RΔz, LΔz, GΔz, CΔz slices — not one lumped RLC network.
RLGCΔzRLGCRLGCR, L, G, C are spread uniformly over the entire length (per metre: Ω/m, H/m, S/m, F/m)each Δz slice looks the same → distributed-parameter network, not a lumped circuit
Distributed view: every Δz slice carries the same RΔz, LΔz, GΔz, CΔz. Credit: redrawn (after Sadiku fig. 11.3).
Why "distributed" matters. The parameters are not lumped at one point — they are spread uniformly along the whole length. A lumped model works only while the line is electrically short. Once the line length is comparable to the wavelength, the phase of the signal changes appreciably along the line, so we must treat R, L, G, C as a continuum and solve differential equations — that is the telegrapher's model of section 3.
FeatureLumped circuitDistributed (transmission line)
Elementsconcentrated at a single pointspread along the entire line, functions of position
Valid whenphysical dimensions ≪ λlength comparable to (or larger than) λ
Analysisordinary algebra / Kirchhoff lawsdifferential equations (∂V/∂z, ∂I/∂z)
ExamplesRC network, resistor on a boardpower line, coax, PCB trace at high f
For each line of length ℓ:   Lℓ = μℓ, Cℓ = εℓ  ⇒  LC = με   and   G/C = σ/ε
Two dimensionally-consistent identities for a homogeneous line — handy as an exam sanity check.

High-frequency L and C of real lines (Table 11.1) — these are what the coax numericals use:

LineL (H/m)C (F/m)
Coax (inner a, outer b)(μ/2π) ln(b/a) 2πε / ln(b/a)
Two-wire (radius a, spacing d)(μ/π) acosh(d/2a) πε / acosh(d/2a)
Coax shortcuts:   L = 2×10⁻⁷ ln(b/a) H/m  (µ = µ₀),   C = 55.6 εₙ/ln(b/a) pF/m
L = (µ₀/2π)ln(b/a) with µ₀/2π = 2×10⁻⁷; C = 2π(8.854×10⁻¹²εŖ)/ln(b/a).
Worked problem · Coaxial cable numbers
A coaxial cable has inner conductor radius 0.45 mm, outer conductor inner radius 1.47 mm and a dielectric with εr = 2.25. Assuming a lossless line, calculate L and C per metre, Z0, the phase velocity and the time delay over a 30 m length.
Setup — a = 0.45 mm, b = 1.47 mm, εŖ = 2.25, lossless line, length 30 m. Find L, C, Z₀, vₖ and the delay.
b/a = 1.47/0.45 = 3.2667 ⇒ ln(b/a) = ln 3.2667 = 1.1838 …(1)
Step 1 — inductance per metre:
L = (µ₀/2π)·ln(b/a) = 2×10⁻⁷ × 1.1838 = 2.368×10⁻⁷ H/m = 236.8 nH/m …(2)
Step 2 — capacitance per metre:
2πε₀εŖ = 2π × 8.854×10⁻¹² × 2.25 = 5.563×10⁻¹¹ × 2.25 = 1.2517×10⁻¹⁰ …(3)
C = 1.2517×10⁻¹⁰/1.1838 = 1.057×10⁻¹⁰ F/m = 105.7 pF/m …(4)
Step 3 — characteristic impedance:
L/C = 236.8×10⁻⁹/105.7×10⁻¹² = 2.240×10³ …(5)
Z₀ = √(2.240×10³) = 47.3 Ω …(6)
Step 4 — phase velocity:
LC = 2.368×10⁻⁷ × 1.057×10⁻¹⁰ = 2.503×10⁻¹⁷ …(7)
vₖ = 1/√(2.503×10⁻¹⁷) = 1/(5.003×10⁻⁹) = 2×10⁸ m/s …(8)
Step 5 — delay over 30 m:
t_d = ℓ/vₖ = 30/(2×10⁸) = 1.5×10⁻⁷ s = 150 ns …(9)
✓ machine-verified

3Telegrapher's equations → wave solutions

Setup. Take an elemental slice of length Δz of the two-conductor line. Over this slice the distributed constants become lumped: series RΔz and LΔz in the conductors, shunt GΔz and CΔz between them. Apply Kirchhoff's laws to this slice, then shrink Δz → 0 to get differential equations. This is the classic textbook derivation.

Worked problem · Why the distributed model?
Draw the equivalent circuit of a differential length Δz of a two-conductor transmission line. Explain why a distributed-parameter model is required instead of a lumped model when the line length is comparable to the wavelength.
A lumped circuit is valid only while dimensions ≪ λ. When the line length is comparable to the wavelength, V and I change appreciably over the line's length, so the line is modelled as a chain of differential slices (each RΔz, LΔz, GΔz, CΔz) and described by differential equations — not by a single RLC network.
criterion: l/λ ≪ 1 ⇒ lumped (one RLC network)   |   l ∼ λ ⇒ distributed (differential slices, telegrapher's equations)
example: a 1 m line at 50 Hz (λ = c/f = 3×10⁸/50 = 6000 km) gives l/λ = 1.7×10⁻⁷ → lumped; the same line at 1 GHz (λ = 30 cm) gives l/λ = 3.3 → distributed. The circuit, not the wire, decides.
RΔzLΔzGΔzCΔzV(z, t)V(z+Δz, t)I(z, t)I(z+Δz, t)Δz (differential slice of line)KVL around the outer loop → ∂V/∂z = −(R I + L ∂I/∂t)KCL at the top node → ∂I/∂z = −(G V + C ∂V/∂t)
Equivalent circuit of a differential length Δz. Credit: redrawn (after Sadiku fig. 11.5).
Derivation path (exam-writable)
1. KVL around the loop:  V(z,t) − RΔz I − LΔz ∂I/∂t − V(z+Δz, t) = 0
2. ÷ Δz, Δz → 0:  ∂V/∂z = −(R I + L ∂I/∂t)
3. KCL at the top node:  I(z,t) − GΔz V − CΔz ∂V/∂t − I(z+Δz, t) = 0
4. Δz → 0:  ∂I/∂z = −(G V + C ∂V/∂t)
these two are the telegrapher's equations (time domain)

Phasor form and the wave equation. With harmonic excitation V(z,t) = Re[Vₙ(z)ejωt], the pair becomes dVₙ/dz = −(R + jωL)Iₙ and dIₙ/dz = −(G + jωC)Vₙ. Differentiate one and substitute the other: both Vₙ and Iₙ obey the same second-order wave equation d²Vₙ/dz² = γ²Vₙ with

γ = α + jβ = √[(R + jωL)(G + jωC)]   (propagation constant, per m)  ·   Z₀ = √[(R + jωL)/(G + jωC)] = R₀ + jX₀
γ = propagation constant; Z₀ = characteristic impedance. Both come straight from the primary constants — memorise these two, every special case follows from them.

General solution. The wave equation's solution is a forward wave (travelling +z, decaying) plus a backward wave (travelling −z):

Vₙ(z) = V₀⁺ e−γz + V₀⁻ eγz     Iₙ(z) = (V₀⁺/Z₀) e−γz − (V₀⁻/Z₀) eγz
In time domain: V(z,t) = V₀ e−αz cos(ωt − βz) — a cosine riding on a decaying envelope, sketched below.
zλ = 2π/βenvelope V0 e−αz (attenuates along z)amplitude shrinks by e−αz (α in Np/m)V(z, t) = V0 e−αz cos(ωt − βz)α = attenuation constant (Np/m) · β = phase constant (rad/m) · both come from γ = α + jβα = attenuation constant (Np/m) · β = phase constant (rad/m) · both come from γ = α + jβ
Snapshot of the forward wave: cosine phase inside an exponentially decaying envelope. Credit: redrawn (after Sadiku fig. 11.7 context).

4α, β, λ, vₖ, Z₀ — meaning + numbers

Physical significance. Writing γ = α + jβ:

λ = 2π/β     vₖ = ω/β = fλ     Z₀ = √[(R+jωL)/(G+jωC)]
1 Np = 8.686 dB — used every time a problem asks "attenuation in dB".
Worked problem · Definitions
Define characteristic impedance and propagation constant of a transmission line. Write their expressions in terms of R, L, G and C.
Setup — a uniform line of primary constants R, L, G, C per metre carries the forward wave V⁺e−γz, I⁺e−γz.
Z₀ ≡ V⁺/I⁺ = √[(R + jωL)/(G + jωC)] …(1)
γ ≡ α + jβ = √[(R + jωL)(G + jωC)] …(2)
Step 1 — where the ratio comes from:
Series drop per metre = (R + jωL)I⁺; shunt current per metre = (G + jωC)V⁺ ⇒ V⁺/I⁺ = (R + jωL)/γ = γ/(G + jωC) …(3)
Step 2 — eliminate γ:
Multiply the two forms in (3): (V⁺/I⁺)² = (R + jωL)/(G + jωC) ⇒ Z₀ = √[(R + jωL)/(G + jωC)] …(4)
Step 3 — result:
Z₀ in Ω (complex unless the line is lossless or distortionless); γ in m⁻¹, with α in Np/m and β in rad/m.
Worked problem · Physical significance
Explain the physical significance of the attenuation constant, phase constant, wavelength and phase velocity of a transmission line, with the relevant expressions.
Setup — write the wave as e−αze−jβz, so α and β act on amplitude and phase separately.
|V(z)| = |V⁺|e−αz ⇒ α = attenuation constant in Np/m …(1)
phase = −βz ⇒ β = phase constant in rad/m …(2)
Step 1 — wavelength:
Phase repeats when βλ = 2π ⇒ λ = 2π/β …(3)
Step 2 — phase velocity:
vₖ = ω/β = (2πf)/(2π/λ) = fλ …(4)
Step 3 — lossless case:
α = 0 and β = ω√(LC) ⇒ vₖ = ω/β = 1/√(LC), independent of f …(5)
Every frequency component travels at the same vₖ ⇒ no dispersion, so the line does not distort the signal.
Worked problem · Open-wire line at 800 Hz
An open-wire line has R = 4 Ω/km, L = 3 mH/km, G = 0.5 µS/km and C = 0.008 µF/km. At 800 Hz, calculate characteristic impedance, propagation constant, phase velocity and wavelength.
Setup — R = 4 Ω/km, L = 3 mH/km, G = 0.5 µS/km, C = 0.008 µF/km, f = 800 Hz. Find Z₀, γ, vₖ, λ.
ω = 2πf = 2π × 800 = 5026.5 rad/s …(1)
Step 1 — series impedance per km:
ωL = 5026.5 × 3×10⁻³ = 15.08 Ω/km …(2)
Z = 4 + j15.08 ⇒ |Z| = √(4² + 15.08²) = √(16 + 227.4) = √243.4 = 15.60 Ω/km …(3)
∠Z = tan⁻¹(15.08/4) = tan⁻¹(3.770) = 75.1° …(4)
Step 2 — shunt admittance per km:
ωC = 5026.5 × 0.008×10⁻⁶ = 4.021×10⁻⁵ S/km …(5)
Y = (0.5 + j40.21)×10⁻⁶ ⇒ |Y| = √(0.25 + 1617)×10⁻⁶ = √1617×10⁻⁶ = 4.021×10⁻⁵ S/km …(6)
∠Y = tan⁻¹(40.21/0.5) = tan⁻¹(80.42) = 89.3° …(7)
Step 3 — characteristic impedance:
Z/Y = (15.60/4.021×10⁻⁵)∠(75.1° − 89.3°) = 3.879×10⁵∠−14.2° …(8)
Z₀ = √(3.879×10⁵)∠(−14.2°/2) = 622.8∠−7.1° …(9)
622.8 cos 7.1° − j622.8 sin 7.1° = 618.0 − j77.0 = 618 − j77 Ω …(10)
Step 4 — propagation constant:
ZY = (15.60 × 4.021×10⁻⁵)∠(75.1° + 89.3°) = 6.274×10⁻⁴∠164.4° …(11)
γ = √(6.274×10⁻⁴)∠(164.4°/2) = 0.02505∠82.2° …(12)
0.02505 cos 82.2° + j0.02505 sin 82.2° = 0.00339 + j0.0248 per km …(13)
α = 3.39 mNp/km = 3.39×10⁻³ × 8.686 = 0.029 dB/km; β = 0.0248 rad/km
Step 5 — velocity and wavelength:
vₖ = ω/β = 5026.5/0.0248 = 2.03×10⁵ km/s …(14)
λ = 2π/β = 6.283/0.0248 = 253 km …(15)
✓ verified
Worked problem · Reverse problem — recover R, L, G, C from Z₀ and γ
At ω = 5000 rad/s a line has Z0 = 397.6∠−35.64° Ω and γ = 0.07953∠54.07° per km. Determine the primary constants R, L, G and C per km, the phase velocity and the wavelength.
Setup — ω = 5000 rad/s, Z₀ = 397.6∠−35.64° Ω, γ = 0.07953∠54.07° per km. Find R, L, G, C, vₖ, λ.
Z = γZ₀ and Y = γ/Z₀, since γ = √(ZY) and Z₀ = √(Z/Y) …(1)
Step 1 — series impedance per km:
|Z| = 0.07953 × 397.6 = 31.62 Ω/km; ∠Z = 54.07° − 35.64° = 18.43° …(2)
R = 31.62 cos 18.43° = 31.62 × 0.9487 = 30 Ω/km …(3)
X = 31.62 sin 18.43° = 31.62 × 0.3162 = 10.0 Ω/km ⇒ L = X/ω = 10.0/5000 = 2×10⁻³ = 2 mH/km …(4)
Step 2 — shunt admittance per km:
|Y| = 0.07953/397.6 = 2.000×10⁻⁴ S/km; ∠Y = 54.07° + 35.64° = 89.71° …(5)
G = 2.000×10⁻⁴ cos 89.71° = 2.000×10⁻⁴ × 5.06×10⁻³ = 1.01×10⁻⁶ S/km ⇒ G ≈ 1 µS/km …(6)
B = 2.000×10⁻⁴ sin 89.71° = 2.000×10⁻⁴ S/km ⇒ C = B/ω = 2.000×10⁻⁴/5000 = 4.0×10⁻⁸ = 0.04 µF/km …(7)
Step 3 — velocity and wavelength:
β = γ sin 54.07° = 0.07953 × 0.8098 = 0.0644 rad/km …(8)
vₖ = ω/β = 5000/0.0644 = 7.76×10⁴ km/s …(9)
λ = 2π/β = 6.283/0.0644 = 97.5 km …(10)
✓ verified (G comes out 1.01 µS/km from the rounded data — the intended answer is 1 µS/km.)

5Lossless, distortionless, low-loss

A. Lossless line (R = 0 = G). Superconducting lines (or a good approximation over short distances) have no series resistance and no leakage. Substituting R = G = 0 into the general γ and Z₀:

α = 0,   γ = jβ = jω√(LC)   |    vₖ = ω/β = 1/√(LC) = 1/√(με)   |   Z₀ = √(L/C) = R₀ (purely real)
No attenuation, velocity independent of frequency, Z₀ real — but note: lossless does not imply distortionless (see C).
Worked problem · Quick lossless numerical
A lossless transmission line has L = 0.25 µH/m and C = 100 pF/m. Calculate its characteristic impedance and phase velocity.
Setup — lossless line, L = 0.25 µH/m, C = 100 pF/m. Find Z₀ and vₖ.
L/C = 0.25×10⁻⁶/100×10⁻¹² = 2.5×10⁻⁷/1.0×10⁻¹⁰ = 2500 …(1)
Step 1 — characteristic impedance:
Z₀ = √(L/C) = √2500 = 50 Ω …(2)
Step 2 — phase velocity:
LC = 0.25×10⁻⁶ × 100×10⁻¹² = 2.5×10⁻¹⁷ …(3)
vₖ = 1/√(LC) = 1/√(2.5×10⁻¹⁷) = 1/(5.0×10⁻⁹) = 2×10⁸ m/s …(4)
✓ verified

B. Distortionless line (R/L = G/C) — derivation. Distortion means different frequency components arrive with different attenuation and delay — the envelope smears. Heaviside's condition removes it. Start from γ² = (R + jωL)(G + jωC) = RG + jω(RC + LG) − ω²LC. This becomes a perfect square when RC = LG:

γ² = RG (1 + jωL/R)²  (using RC = LG)  ⇒  γ = √(RG) + jω√(LC)
⇒ α = √(RG) (frequency-independent!)  ·  β = ω√(LC) (linear in f)  ·  vₖ = 1/√(LC) (constant)  ·  Z₀ = √(L/C) = R₀ google: Heaviside condition distortionless transmission line R/L = G/C
All frequencies attenuate equally and travel at the same speed ⇒ no distortion. This is why old telephone lines were "loaded" with extra inductance (section 9).

C. Low-loss line. Real RF lines (coax) are not exactly lossless but R ≪ ωL and G ≪ ωC. Expanding the general expressions to first order:

α ≈ R/(2Z₀) + G Z₀/2   ·   β ≈ ω√(LC)   ·   Z₀ ≈ √(L/C)
Good to ~1% when R≪ωL — this is the working formula for the B8-type numerical.
Worked problem · Distortionless condition
State the condition for a distortionless line. Write the expressions for α, β and Z0 under this condition.
Setup — require the same attenuation and the same velocity at every frequency.
Condition: R/L = G/C …(1)
Step 1 — factor the series impedance:
R + jωL = L(R/L + jω) = L(k + jω), with k ≡ R/L …(2)
Step 2 — factor the shunt admittance:
G + jωC = C(G/C + jω) = C(k + jω), using (1) …(3)
Step 3 — characteristic impedance:
Z₀ = √[(R + jωL)/(G + jωC)] = √[L(k + jω)/C(k + jω)] = √(L/C) ⇒ purely real …(4)
Step 4 — propagation constant:
γ = √[(R + jωL)(G + jωC)] = √[LC(k + jω)²] = (k + jω)√(LC) …(5)
α = k√(LC) = √(RG/LC)·√(LC) = √(RG), independent of ω …(6)
β = ω√(LC) ⇒ vₖ = ω/β = 1/√(LC), independent of ω …(7)
Worked problem · Lossless line characteristics
Explain the characteristics of a lossless transmission line. Obtain its α, β, Z0 and phase velocity from the general expressions and show that Z0 is purely real.
Setup — set R = 0 and G = 0 in the general expressions.
Z₀ = √[(R + jωL)/(G + jωC)] = √(jωL/jωC) = √(L/C) …(1)
Step 1 — propagation constant:
γ = √[(jωL)(jωC)] = √(−ω²LC) = jω√(LC) …(2)
γ = α + jβ ⇒ α = 0 (no attenuation) and β = ω√(LC) …(3)
Step 2 — phase velocity:
vₖ = ω/β = ω/(ω√(LC)) = 1/√(LC) = 1/√(µε) …(4)
Step 3 — Z₀ is real:
Z₀² = L/C is a positive real number ⇒ Z₀ = R₀ + j0, purely real …(5)
Caseγ = α + jβ Z₀vₖ
General (lossy)√[(R+jωL)(G+jωC)] √[(R+jωL)/(G+jωC)]ω/β
Lossless0 + jω√(LC)√(L/C) = R₀ 1/√(LC)
Distortionless√(RG) + jω√(LC) √(L/C) = R₀1/√(LC)
Lossless vs distortionless (common trap). Both have real Z₀ = √(L/C) and β = ω√(LC), but the lossless line has α = 0 while the distortionless line only requires α = √(RG) to be frequency-independent. A lossless line is automatically distortionless; a distortionless line is generally lossy — telephone lines are deliberately loaded to become distortionless, accepting some loss.
Worked problem · Design a distortionless line
A distortionless line is required to have Z0 = 75 Ω, α = 0.03 Np/m and a phase velocity of 0.7c. Determine R, L, G and C per metre, and the wavelength at 150 MHz.
Setup — Z₀ = 75 Ω, α = 0.03 Np/m, vₖ = 0.7c, f = 150 MHz. Find R, L, G, C and λ.
vₖ = 0.7 × 3×10⁸ = 2.1×10⁸ m/s …(1)
Step 1 — the LC product:
LC = 1/vₖ² = 1/(2.1×10⁸)² = 1/(4.41×10¹⁶) = 2.268×10⁻¹⁷ ⇒ √(LC) = 4.762×10⁻⁹ …(2)
Step 2 — L and C:
L = √(LC)·Z₀ = 4.762×10⁻⁹ × 75 = 3.571×10⁻⁷ = 357 nH/m …(3)
C = √(LC)/Z₀ = 4.762×10⁻⁹/75 = 6.349×10⁻¹¹ = 63.5 pF/m …(4)
Step 3 — R and G from α:
R = αZ₀ = 0.03 × 75 = 2.25 Ω/m …(5)
G = α/Z₀ = 0.03/75 = 4.0×10⁻⁴ = 0.4 mS/m …(6)
Step 4 — check the distortionless condition:
R/L = 2.25/3.571×10⁻⁷ = 6.30×10⁶; G/C = 4.0×10⁻⁴/6.349×10⁻¹¹ = 6.30×10⁶ ✓ …(7)
Step 5 — wavelength:
β = ω√(LC) = (2π × 1.5×10⁸) × 4.762×10⁻⁹ = 9.425×10⁸ × 4.762×10⁻⁹ = 4.49 rad/m …(8)
λ = vₖ/f = 2.1×10⁸/1.5×10⁸ = 1.4 m …(9)
✓ verified
Worked problem · Low-loss line at 500 MHz
A low-loss line has R = 0.1 Ω/m, L = 0.2 µH/m, G = 10 µS/m and C = 80 pF/m. At 500 MHz, calculate Z0, α, β, the wavelength, the phase velocity and the total attenuation in dB over 50 m.
Setup — R = 0.1 Ω/m, L = 0.2 µH/m, G = 10 µS/m, C = 80 pF/m, f = 500 MHz, ℓ = 50 m. Find Z₀, α, β, λ, vₖ and the loss in dB.
ω = 2π × 5×10⁸ = 3.1416×10⁹ rad/s …(1)
Step 1 — check the low-loss assumption:
ωL = 3.1416×10⁹ × 0.2×10⁻⁶ = 628.3 Ω/m; ωC = 3.1416×10⁹ × 80×10⁻¹² = 0.2513 S/m …(2)
R/ωL = 0.1/628.3 = 1.6×10⁻⁴ ≪ 1 and G/ωC = 10×10⁻⁶/0.2513 = 4.0×10⁻⁵ ≪ 1 ⇒ low-loss formulas valid …(3)
Step 2 — characteristic impedance:
L/C = 0.2×10⁻⁶/80×10⁻¹² = 2.0×10⁻⁷/8.0×10⁻¹¹ = 2500 …(4)
Z₀ = √2500 = 50 Ω (exact complex value 50.0∠−0.003°) …(5)
Step 3 — attenuation constant:
R/(2Z₀) = 0.1/(2 × 50) = 1.0×10⁻³ Np/m …(6)
GZ₀/2 = (10×10⁻⁶ × 50)/2 = 2.5×10⁻⁴ Np/m …(7)
α = 1.0×10⁻³ + 2.5×10⁻⁴ = 1.25 mNp/m …(8)
Step 4 — phase constant and wavelength:
√(LC) = √(0.2×10⁻⁶ × 80×10⁻¹²) = √(1.6×10⁻¹⁷) = 4.0×10⁻⁹ …(9)
β = ω√(LC) = 3.1416×10⁹ × 4.0×10⁻⁹ = 12.57 rad/m …(10)
λ = 2π/β = 6.283/12.57 = 0.5 m; vₖ = ω/β = 3.1416×10⁹/12.57 = 2.5×10⁸ m/s …(11)
Step 5 — loss over 50 m:
αℓ = 1.25×10⁻³ × 50 = 0.0625 Np …(12)
Loss = 0.0625 × 8.686 = 0.54 dB …(13)
✓ verified

6Input impedance Zₖₙ

Why it matters. Everything the source "sees" is the input impedance of the line-plus-load combination. Zₖₙ depends on the load, on Z₀, and on the electrical length βℓ of the line — which is why the same antenna can look completely different through different cable lengths.

(a) line of length ℓ, terminated in ZₗV₀Iline (Z₀, γ)length ℓZin= V(z)/I(z) looking into the lineZₗzz = 0z = ℓ(b) seen from the sourceV₀ZinZₗ = Vₗ/Iₗ at z = ℓ → solve for V⁺, V⁻ → Zₖₙ = Z₀ (Zₗ + Z₀ tanh γℓ) / (Z₀ + Zₗ tanh γℓ)
(a) Line of length ℓ terminated in Zₗ; (b) the same line replaced by its input impedance. Credit: redrawn (after Sadiku fig. 11.6).

Derivation route (exam-writable). Write the general solution at z = ℓ (Vₗ = V(ℓ), Iₗ = I(ℓ)), solve for the wave amplitudes V₀⁺ = ½(Vₗ + Z₀Iₗ)eγℓ and V₀⁻ = ½(Vₗ − Z₀Iₗ)e−γℓ, then form V(z)/I(z) at z = 0. Collecting terms with the identities cosh γℓ = (eγℓ + e−γℓ)/2 and sinh γℓ = (eγℓ − e−γℓ)/2:

Zₖₙ = Z₀ (Zₗ + Z₀ tanh γℓ) / (Z₀ + Zₗ tanh γℓ)   (general line)
lossless (α = 0, γ = jβ):  Zₖₙ = Z₀ (Zₗ + jZ₀ tan βℓ) / (Z₀ + jZₗ tan βℓ)
βℓ is called the electrical length (in degrees or radians). Every special-length result of section 8 drops out of this one formula.

7Reflection coefficient, SWR, return loss, power

Mismatch creates a reflected wave. If the load is not Z₀, the backward wave is not zero and the line carries standing waves. The whole phenomenon is governed by the reflection coefficient at the load:

Γₗ = (Zₗ − Z₀)/(Zₗ + Z₀) = |Γ|ejφŖ   ·   Γ(z) = |Γ|ej(φŖ−2βz)   ·   Iₖ(z) = −Γ(z) (current reflection coeff = −voltage one)
Γ = 0 is the perfect match; |Γ| = 1 for open or short (total reflection).
S = Vₖₔₙ/Vₖₙₙ = (1 + |Γ|)/(1 − |Γ|)   ·   |Γ| = (S − 1)/(S + 1)   ·   RL = −20 log₁₀|Γ| dB (return loss)
|V|ₖₔₙ = |V₀⁺|(1 + |Γ|) · |V|ₖₙₙ = |V₀⁺|(1 − |Γ|) — V max lines up with I min, a quarter wavelength apart.
S = 1 for a matched line, ∞ for open/short. Return loss of 40 dB means only 1% of the power is reflected — values of 35–60 dB are considered good.

Power. On a lossless line the average input power is the incident power minus the reflected power; it does not depend on position:

Pₖₙ = (|V₀⁺|²/2Z₀)(1 − |Γ|²) = Pₖₙₖ − PŖₖₜ
Maximum power transfer ⇒ Γ = 0. The factor (1 − |Γ|²) is the fraction of power that actually reaches the load.
|V| (V rms)Z₀ = 50 Ω, Zₗ = 100 Ω100500|V|ₖₔₙ = 100|V|ₖₙₙ = 50S = 100/50 = 2|I| (A rms)210|I|ₖₙₙ = 1|I|ₖₔₙ = 2ℓ0λ/4λ/23λ/4λ1.5λdistance from the load ℓ — I max where V min (a quarter wave apart); pattern repeats every λ/2
Standing waves for Z₀ = 50 Ω with Zₗ = 100 Ω, Vₗ = 100 V rms: |V| swings 50–100 V, |I| swings 1–2 A, S = 2, pattern repeats every λ/2. Credit: redrawn (after Sadiku fig. 11.7).
Worked example
A 50-Ω line, u = 0.6c, is terminated in Zₗ = 60 + j40 Ω; the line is 30 m long at 2 MHz. Find Γ, S and Zₖₙ.
Setup — Z₀ = 50 Ω, Zₗ = 60 + j40 Ω, ℓ = 30 m, f = 2 MHz, u = 1.8×10⁸ m/s. Find βℓ, Γₗ, S and Zₖₙ.
βℓ = 2πfℓ/u = (2π × 2×10⁶ × 30)/(1.8×10⁸) = (2π × 60×10⁶)/(1.8×10⁸) = 2π/3 = 2.094 rad = 120° …(1)
tan 120° = −tan 60° = −1.732 …(2)
Step 1 — load reflection coefficient:
Γₗ = (Zₗ − Z₀)/(Zₗ + Z₀) = (60 + j40 − 50)/(60 + j40 + 50) = (10 + j40)/(110 + j40) …(3)
|num| = √(10² + 40²) = √1700 = 41.23; ∠num = tan⁻¹(40/10) = 76.0° …(4)
|den| = √(110² + 40²) = √13700 = 117.05; ∠den = tan⁻¹(40/110) = 20.0° …(5)
Γₗ = (41.23/117.05)∠(76.0° − 20.0°) = 0.352∠56.0° …(6)
Step 2 — standing-wave ratio:
S = (1 + |Γₗ|)/(1 − |Γₗ|) = (1 + 0.352)/(1 − 0.352) = 1.352/0.648 = 2.09 …(7)
Step 3 — input impedance:
Zₖₙ = Z₀(Zₗ + jZ₀ tan βℓ)/(Z₀ + jZₗ tan βℓ) …(8)
Zₗ + jZ₀ tan βℓ = 60 + j40 + j50(−1.732) = 60 + j40 − j86.60 = 60 − j46.60 …(9)
jZₗ tan βℓ = j(60 + j40)(−1.732) = j(−103.92 − j69.28) = 69.28 − j103.92 …(10)
Z₀ + jZₗ tan βℓ = 50 + 69.28 − j103.92 = 119.28 − j103.92 …(11)
|num| = √(60² + 46.60²) = √5772 = 75.97; ∠num = tan⁻¹(−46.60/60) = −37.9° …(12)
|den| = √(119.28² + 103.92²) = √25026 = 158.2; ∠den = tan⁻¹(−103.92/119.28) = −41.1° …(13)
Zₖₙ = 50 × (75.97/158.2)∠(−37.9° + 41.1°) = 50 × 0.480∠3.2° = 24∠3.2° Ω = 24 + j1.35 Ω …(14)
✓ verified

8Short, open, matched + λ/8, λ/4, λ/2 lines

Three standard loads. Put Zₗ = 0 (short), Zₗ → ∞ (open) and Zₗ = Z₀ (matched) into the lossless Zₖₙ formula:

LoadZₖₙΓₗ SComment
Short (Zₗ = 0)jZ₀ tan βℓ−1 ∞pure reactance; βℓ < 90° looks inductive
Open (Zₗ → ∞)−jZ₀ cot βℓ +1∞dual of the short; βℓ < 90° looks capacitive
Matched (Zₗ = Z₀)Z₀01 no reflection — whole wave absorbed, max power transfer

Three standard lengths (for a lossless line, any load): setting βℓ = π/4, π/2 and π/4×½ in the Zₖₙ formula gives the results every exam reuses:

λ/8 lineβℓ = π/4ZₗZinZₖₙ = R₀ (Zₗ + jR₀) / (R₀ + jZₗ)|Zₖₙ| = R₀ (turns any Rₗ into |Z| = R₀)(lossless line)λ/4 lineβℓ = π/2ZₗZinZₖₙ = Z₀² / Zₗquarter-wave transformer: choose Z₀ = √(Zₖₙ Zₗ) to match(lossless line)λ/2 lineβℓ = πZₗZinZₖₙ = Zₗ1 : 1 transformer — the load repeats itself(lossless line)all three from one formula: Zₖₙ = Z₀ (Zₗ + jZ₀ tan βℓ) / (Z₀ + jZₗ tan βℓ)
The λ/8, λ/4 and λ/2 line results. Credit: original drawing for these notes (after Sadiku sec. 11.5).
λ/4: Zₖₙ = Z₀²/Zₗ — impedance inverter. Matching trick: insert a quarter-wave section with Z₀′ = √(Zₖₙ Zₗ) between a Zₖₙ line and a resistive load Zₗ. A shorted λ/4 stub looks open, and vice versa.
λ/2: Zₖₙ = Zₗ — the load repeats itself (1:1 transformer). λ/8: |Zₖₙ| = R₀ for any resistive load.

9Big line problems (100 km line, cable loading)

Two Part-C classics that combine everything from sections 3–5: a long lossy line worked end-to-end, and a telephone cable that fails the Heaviside test and has to be loaded back into shape.

Worked problem · 100 km line, matched load
A 100 km line has R = 6 Ω/km, L = 2.2 mH/km, G = 0.05 µS/km and C = 0.005 µF/km. It is terminated in its characteristic impedance and fed with 10 V (rms) at 1 kHz. Calculate Z0, γ, the sending-end current, the receiving-end voltage and current, the line attenuation in dB and the transmission efficiency.
Setup — R = 6 Ω/km, L = 2.2 mH/km, G = 0.05 µS/km, C = 0.005 µF/km; Vₙ = 10 V rms at 1 kHz; ℓ = 100 km, terminated in Z₀. Find Z₀, γ, Iₙ, VŖ, IŖ, attenuation in dB and efficiency.
ω = 2π × 1000 = 6283.2 rad/s …(1)
Step 1 — series impedance per km:
ωL = 6283.2 × 2.2×10⁻³ = 13.82 Ω/km …(2)
Z = 6 + j13.82 ⇒ |Z| = √(6² + 13.82²) = √(36 + 191.0) = √227.0 = 15.07 Ω/km …(3)
∠Z = tan⁻¹(13.82/6) = tan⁻¹(2.303) = 66.5° …(4)
Step 2 — shunt admittance per km:
ωC = 6283.2 × 0.005×10⁻⁶ = 3.142×10⁻⁵ S/km …(5)
Y = (0.05 + j31.42)×10⁻⁶ ⇒ |Y| = 3.142×10⁻⁵ S/km; ∠Y = tan⁻¹(31.42/0.05) = 89.9° …(6)
Step 3 — characteristic impedance:
Z/Y = (15.07/3.142×10⁻⁵)∠(66.5° − 89.9°) = 4.796×10⁵∠−23.4° …(7)
Z₀ = √(4.796×10⁵)∠(−23.4°/2) = 692.5∠−11.7° …(8)
692.5 cos 11.7° − j692.5 sin 11.7° = 678.1 − j140.4 = 678 − j140 Ω …(9)
Step 4 — propagation constant:
ZY = (15.07 × 3.142×10⁻⁵)∠(66.5° + 89.9°) = 4.735×10⁻⁴∠156.4° …(10)
γ = √(4.735×10⁻⁴)∠(156.4°/2) = 0.02176∠78.2° = 0.00444 + j0.0213 per km …(11)
Step 5 — sending-end current:
Iₙ = Vₙ/Z₀ = 10/692.5∠−11.7° = 14.44∠11.7° mA …(12)
Step 6 — receiving end over 100 km:
αℓ = 0.00444 × 100 = 0.444 Np ⇒ e−0.444 = 0.6414 …(13)
VŖ = 10 × 0.6414 = 6.41 V; IŖ = 14.44 × 0.6414 = 9.26 mA …(14)
Step 7 — attenuation in dB:
0.444 Np × 8.686 = 3.86 dB …(15)
Step 8 — efficiency:
η = PŖ/Pₙ = e−2αℓ = e−0.889 = 41.1% …(16)
✓ verified
Because the line is matched, V/I = Z₀ everywhere, so the power factor is the same at both ends and η reduces to e−2αℓ. A 100 km line at 1 kHz is brutally lossy — this is why telephone systems used repeaters and loading.
Worked problem · Distortion check + inductive loading
A cable has R = 10 Ω/km, L = 1 mH/km, G = 10 µS/km and C = 0.05 µF/km. (i) Check whether it is distortionless. (ii) Calculate α and the phase velocity at 500 Hz, 1 kHz and 3 kHz and comment on the distortion. (iii) Find the inductance to be added per km to make it distortionless, and the resulting Z0, α and phase velocity.
Setup — R = 10 Ω/km, L = 1 mH/km, G = 10 µS/km, C = 0.05 µF/km. (i) distortionless? (ii) α and vₖ at 500 Hz, 1 kHz, 3 kHz; (iii) loading.
R/L = 10/1×10⁻³ = 1.0×10⁴ …(1)
G/C = 10×10⁻⁶/0.05×10⁻⁶ = 200 …(2)
1.0×10⁴ ≠ 200 ⇒ not distortionless …(3)
Step 1 — α and vₖ versus frequency (γ = √(ZY), vₖ = ω/β):
fα (Np/km)β (rad/km) vₖ (km/s)
500 Hz0.02510.03209.83×10⁴
1 kHz0.03030.05281.19×10⁵
3 kHz0.03500.13741.37×10⁵
Step 1 — read the table:
α rises 0.0251 → 0.0303 → 0.0350 Np/km and vₖ rises 9.83×10⁴ → 1.19×10⁵ → 1.37×10⁵ km/s as f goes 500 Hz → 1 kHz → 3 kHz …(1)
High-frequency speech components arrive later and weaker than low ones ⇒ the line distorts speech …(2)
Step 2 — inductance needed for R/L′ = G/C:
L′ = RC/G = (10 × 0.05×10⁻⁶)/(10×10⁻⁶) = 5.0×10⁻⁷/1.0×10⁻⁵ = 0.05 H/km …(3)
ΔL = L′ − L = 50 − 1 = 49 mH/km …(4)
Step 3 — constants after loading:
Z₀ = √(L′/C) = √(0.05/5×10⁻⁸) = √(1.0×10⁶) = 1000 Ω …(5)
α = √(RG) = √(10 × 10×10⁻⁶) = √(1.0×10⁻⁴) = 0.01 Np/km, frequency-independent …(6)
vₖ = 1/√(L′C) = 1/√(0.05 × 5×10⁻⁸) = 1/√(2.5×10⁻⁹) = 1/(5.0×10⁻⁵) = 2×10⁴ km/s, frequency-independent …(7)
✓ verified
fα (Np/km)β (rad/km) vₖ (km/s)
500 Hz0.02510.03209.83×10⁴
1 kHz0.03030.05281.19×10⁵
3 kHz0.03500.13741.37×10⁵
α rises and vₖ rises with frequency ⇒ high-frequency speech components arrive later and weaker than low ones — the line distorts speech.
(iii) Loading: require R/L′ = G/C ⇒ L′ = RC/G = 10 × 0.05×10⁻⁶ / 10×10⁻⁶ = 0.05 H/km.
Add ΔL = 50 − 1 = 49 mH/km. After loading:
Z₀ = √(L′/C) = √(0.05/5×10⁻⁸) = 1000 Ω · α = √(RG) = √(10×10⁻ⁱ) = 0.01 Np/km (frequency-independent) · vₖ = 1/√(L′C) = 2×10⁴ km/s (frequency-independent) ✓ verified

10EMI vs EMC, classification, sources

The problem and the solution. EMI (electromagnetic interference) is the degradation in the performance of a device due to the fields making up the electromagnetic environment — unwanted voltages or currents that disturb proper operation. EMC (electromagnetic compatibility) is the solution: a device functions satisfactorily in its environment without introducing intolerable disturbances into that environment. EMC is achieved by proven design techniques (grounding, shielding, filtering) rather than by luck.

Worked problem · EMI vs EMC with examples
Distinguish between electromagnetic interference (EMI) and electromagnetic compatibility (EMC), with one example of each.
Setup — EMI is an event; EMC is a property of the finished design.
EMI: unwanted EM energy couples from a source into a victim and degrades its performance …(1)
EMC: the device both emits below the limit and survives the immunity level, in the same environment …(2)
Step 1 — example of EMI:
A personal computer radiates broadband noise → picked up by a nearby FM receiver (ghosting on a TV picture, speech interruption on a police radio) …(3)
Step 2 — example of EMC by design:
Shield a switching supply inside a grounded metal enclosure ⇒ the supply and the radio next to it both keep working …(4)
So EMI is the failure; EMC is the state reached when the emission and immunity margins are both met.

Classification. The cause may be within the system (intrasystem EMI — e.g. a motor inside the same cabinet noise-ing up its own amplifier) or from outside (intersystem EMI — e.g. a broadcast transmitter hitting a hi-fi). The source of EMI is the emitter; the disturbed device is the susceptor (victim). Both kinds are controllable by the design engineer through grounding/wiring, shielding and filtering.

intersystem_emi
Typical intersystem EMI scene — every emitter (E) threatens susceptible equipment (S) nearby. Credit: reused from lecture deck, slide 61 (Sadiku fig. 13.5).

Sources of EMI. Three families: (1) intrinsic noise — random fluctuations inside physical systems (thermal noise, shot noise); (2) man-made sources — motors, switches, computers/digital electronics, radio transmitters, power lines; (3) natural disturbances — lightning, sunspots. Distinguish noise from interference: interference is the undesirable effect of noise when it causes improper operation — noise itself cannot be eliminated, but interference can be controlled.

11Source–path–victim + coupling mechanisms

The three-element model. Every EMI problem needs all three of a source, a coupling path and a victim — remove any one and the problem disappears. This gives the engineer exactly three places to attack: quiet the source, block the path, or harden the victim.

SOURCEemitter: transmitter, motor,switch, digital clock, ESDCOUPLING PATHconduction · capacitance ·inductance · radiationVICTIMsusceptor: receiver, amplifier,microcontroller, sensornoisenoiseall three must exist for interference — kill any one and the EMI problem is gonecontrol options: quiet the source · block the path · harden the victim
The universal EMI block model. Credit: original drawing for these notes (after Ott, Electromagnetic Compatibility Engineering).

Four coupling mechanisms. The noise travels from source to victim by conduction, by electric fields, by magnetic fields, or through space as a radiated wave — recognising which one dominates decides which fix works.

conductive (common impedance)Ckt 1Ckt 2shared return:Z commoncurrents share a wire → i·Z drops noise volts into bothcapacitive (E-field)line Aline Bstray C betweenconductorsi = C dV/dthigher f → morenearby HV wire injects current into signal wireinductive (H-field, magnetic)loop 1 (noise i)loop 2 picks upM di/dttwo loops share magnetic flux → mutual-inductance pickupradiative (far field)transmittervictim antennaenergy travels as EM wave: cables act as antennas
The four coupling mechanisms. Credit: original drawings for these notes (after Ott ch. 2).
Worked problem · Model + four mechanisms with examples
Explain the source, coupling path and victim model of an EMI problem with a neat block diagram. Describe the four coupling mechanisms (conductive, capacitive, inductive and radiative) with one example each.
Setup — every EMI problem is a source → coupling path → victim chain.
Source (e.g. a switching transistor) → coupling path → victim (e.g. an amplifier) …(1)
Step 1 — conductive coupling:
Noise current shares a conductor: v = i·Z_common ⇒ the i·Z drop of one circuit appears in the other (two circuits sharing a ground wire) …(2)
Step 2 — capacitive coupling:
Stray capacitance injects i = C·dV/dt ⇒ a power cable running next to a signal cable …(3)
Step 3 — inductive coupling:
Mutual inductance couples di/dt: v = M·di/dt ⇒ the field of a relay-coil loop induces voltage in a nearby signal loop …(4)
Step 4 — radiative coupling:
Source and victim act as antennas ⇒ a handheld transmitter's field is picked up by a receiver's cable …(5)

12Conducted vs radiated, emission & immunity, the 4 tests

Two origins of EMI. Conducted emissions are noise voltages/currents carried along metallic paths — typically out of the equipment's power cord onto the common power network, where they bother everything else plugged in. Radiated emissions are the E and/or H fields the device radiates through space, picked up by other electronics. Every EMC standard regulates both, because every product is both a transmitter and a receiver of junk.

EQUIPMENTSMPS, computer, dimmerradiated emissions(E and/or H fields, 30 MHz – 1 GHz+)power cordcommon powernetwork (mains)conducted emissions(1 kHz – 30 MHz on mains)other devices onthe same mainsinterferencenearby receiverradio, TV, sensor boardpicked up through spaceEMC has two aspects: limit what you EMIT (conducted + radiated) and harden what you can SUSPECT (immunity)
Conducted (via the power cord and mains) vs radiated (through space) emissions from one device. Credit: redrawn (after Sadiku fig. 13.24).

Emission vs susceptibility. EMC has two aspects. Emission is the interference-causing potential of a product — controlling it limits the EM environment everyone else must live in. Susceptibility is the capability of a device to respond to unwanted EM energy; its opposite is immunity — the maximum EM environment in which the equipment still works to spec, with a defined safety margin.

The four test categories. Compliance labs run four kinds of tests, two on what leaks out, two on what the device can stand:

TestMeasures
Conducted emissionnoise voltage/current the device pushes onto its power/signal lines (LISN + receiver, 150 kHz–30 MHz)
Radiated emissionfield strength radiated by the device, measured with calibrated antennas on an open-area site or in a chamber (30 MHz–1 GHz+)
Conducted susceptibilitydoes the device still work when RF/burst noise is deliberately injected onto its power and signal lines?
Radiated susceptibilitydoes it still work inside a known radiated field (antenna or cell in a chamber)?
Worked problem · Sources + the four tests
List the natural and man-made sources of EMI. Name the four categories of EMI/EMC tests (conducted emission, radiated emission, conducted susceptibility, radiated susceptibility) and state what each one measures.
Setup — classify the sources, then classify the four tests by what each one measures.
Natural sources: lightning, sunspots (plus intrinsic thermal/shot noise inside devices) …(1)
Man-made: motors, switches, computers and digital electronics, radio transmitters, power lines …(2)
Step 1 — emission tests (noise leaving the equipment):
Conducted emission: noise out on the lines, as VdBµV = 20 log₁₀(V/1 µV) …(3)
Radiated emission: fields out through space, as EdBµV/m = 20 log₁₀(E/1 µV/m) …(4)
Step 2 — susceptibility (immunity) tests (noise entering):
Conducted susceptibility: survives injected line noise …(5)
Radiated susceptibility: survives an applied field …(6)
Worked problem · Susceptibility + microcontroller case
Explain conducted and radiated susceptibility (immunity) and how they are tested. A microcontroller board resets whenever a nearby relay switches or a mobile phone is held close to it. Analyze the likely coupling path in each case and propose suitable measures (filtering, shielding, grounding, layout) to make the board compliant.
Setup — immunity is tested by injecting the disturbance and watching for malfunction.
Conducted susceptibility: RF, fast transients and surges injected through coupling networks onto the mains and I/O lines while the unit is monitored …(1)
Radiated susceptibility: the board is exposed to a calibrated field from an antenna in a screened chamber …(2)
Step 1 — case 1, relay switching:
Coil interrupt gives a fast di/dt burst: v = M·di/dt couples inductively, the shared ground/supply couples conductively, and the spark also radiates …(3)
Fixes: flyback diode/snubber across the coil; separate ground returns; decoupling caps at the MCU; RC filter + Schmitt on RESET; short reset traces away from power wiring …(4)
Step 2 — case 2, mobile phone held close:
GSM burst at ~900/1800 MHz is a strong radiated RF field, demodulated by nonlinear junctions or picked up on cables/loops, upsetting the reset/power rails …(5)
Burst duty cycle 1/8 ⇒ peak-to-average = 10 log₁₀8 = 10 × 0.903 = 9.0 dB, so the peak field is ~9 dB above the average …(6)
Fixes: local RF shielding can, ferrites on cables, shorter/grounded I/O, ground plane, filtering on reset and supply, software watchdog …(7)
Together: filter + shield + ground + layout.

13Conducted emission, CM/DM currents, the LISN

Conducted emission testing. The equipment (EUT) is plugged to a clean mains through a Line Impedance Stabilisation Network (LISN) — an "artificial mains". It does three jobs: (1) presents the EUT a standard, stable 50 Ω RF impedance so measurements are repeatable; (2) couples the noise on L and N to a 50-Ω test receiver (read in dBµV); (3) isolates the EUT from mains noise coming in from the wall.

(a) LISN — artificial mains for conducted-emission testsEUTequipmentLNLISN (50 Ω // 50 µH per line)50 Ωtest receiver (dBµV)mains portLISN = stable 50 Ω impedance for the EUT + clean coupling of noise to the receiver(b) differential-mode vs common-mode noise currentssourceloadiₗₙₘ : go and returnnormal signal path current (loop area small)sourceloadiₖₘₘ : same way on both wiresreturns via stray C / groundleakage through parasitics — the harder one to filter
(a) LISN block schematic; (b) differential-mode vs common-mode noise currents. Credit: original drawing for these notes (after CISPR 16 / Ott ch. 11).

Two modes of conducted noise. Differential mode (DM): current goes down one line and returns on the other — the "normal" circuit loop; filter with X-caps and series chokes. Common mode (CM): equal currents flow the same direction on both lines and return through stray capacitance/ground — parasitic leakage, usually the bigger offender at high frequency; filter with Y-caps to earth and common-mode chokes.

Worked problem · SMPS noise vs the limit
A switched-mode power supply produces a conducted noise voltage of 2 mV across the 50 Ω port of a LISN. Express the noise in dBµV and the noise current in dBµA. If the limit is 56 dBµV, find by how much it is exceeded and the minimum filter insertion loss needed for a 6 dB margin.
Setup — V = 2 mV across the 50 Ω LISN port, limit 56 dBµV. Find dBµV, dBµA, the excess and the insertion loss for a 6 dB margin.
V/1 µV = 2×10⁻³/1×10⁻⁶ = 2000 …(1)
Step 1 — noise voltage in dBµV:
20 log₁₀(2000) = 20 × 3.301 = 66.02 dBµV …(2)
Step 2 — noise current and dBµA:
I = V/R = 2×10⁻³/50 = 4.0×10⁻⁵ A = 40 µA …(3)
20 log₁₀(40) = 20 × 1.602 = 32.04 dBµA …(4)
Step 3 — excess over the limit:
66.02 − 56 = 10.02 dB over the limit …(5)
Step 4 — insertion loss for a 6 dB margin:
IL ≥ 10.02 + 6 = 16.02 dB …(6)
✓ verified

14Grounding, shielding, filtering

The three suppression tools. Almost every intrasystem EMC fix reduces to one of three moves: give junk currents a path to earth, keep radiated energy where it belongs, or filter what is left on the wires. They are complementary — good grounding reduces how much shielding and filtering you need, and good shielding reduces how much filtering you need.

1groundingcircuitlow-Z path to earth /zero-V reference planegives unwanted currents an exit2shieldingcktmetal box confinesor blocks radiatedenergy (solid/screen/braid)keeps fields in — or out3filteringLCnoisy mainscleanlow-pass blocks HF conducted noisethe three suppression tools — good grounding can reduce the need for shielding and filtering,good shielding can reduce the need for filtering
The three techniques at a glance. Credit: original drawing for these notes.

15Shielding effectiveness — skin depth, A, R, M

Definition. The shielding effectiveness of a shield is the ratio of field strength without the shield to field strength with it, in dB: SE = 20 log₁₀(E₁/E₂) dB (same form for H or power). A plane-wave shield eats the wave three ways — absorption, reflection, and a multiple-reflection correction:

SE (dB) = A + R + M
A = 8.686 t/δ dB (absorption: wave decays e−t/δ crossing thickness t)
R = 20 log₁₀(|η₀| / 4|ηₙ|) dB (reflection at the air↔metal faces; η₀ = 377 Ω)
|ηₙ| = √(ωμ/σ) (intrinsic impedance of the good conductor) · M ≈ 0 when t ≫ δ (rule of thumb: A > 15 dB)
δ = skin depth = 1/√(πfμσ). Multiple reflections matter only in thin shields where the two faces "see" each other.
air, η₀ = 377 Ωshield, tprotected regionincidentreflectedreflection loss Rwave decays e−t/δabsorption loss Aweakweak transmitted waveM = multiple-reflection correction (big only when t ≪ δ)SE (dB) = A + R + M — A = 8.686 t/δ · R = 20 log₁₀(|η₀| / 4|ηₙ|)
Plane wave → conducting sheet: reflected at the entry face, absorbed inside, weak remainder exits; M counts internal bounces. Credit: original drawing for these notes (after Ott ch. 6).
surface (x = 0)conductorJ₀J = J₀/eδ (skin depth)δ = 1/√(πfμσ)current crowds toward the surfacet ≫ δ → good shieldingA = 8.686 t/δ dBf↑ (or μ, σ ↑) → δ↓why thick, conductive, high-μ shields absorb more: the wave cannot penetrate far
Skin effect: current density falls as e−x/δ below the surface. Credit: original drawing for these notes (after Sadiku sec. 10.10 context).

What moves the numbers. Higher frequency, higher conductivity and higher permeability all shrink δ, so A grows with f, σ, μ and thickness — but R falls with frequency (because |ηₙ| √f grows toward 377 Ω). For magnetic materials μŖ ≫ 1 helps absorption but hurts reflection (ηₙ rises). Any aperture (seam, hole, ventilation slot) with a long dimension near λ/2 leaks like an open window — seams must be conductive-gasketed and holes kept ≪ λ/20 to keep the box shielding.

Worked problem · Definition
Define shielding effectiveness. Write its expression in dB in terms of the electric field with and without the shield.
Setup — compare the field at the same point with and without the shield.
SE = 20 log₁₀(E₁/E₂) dB, with E₁ = field without the shield and E₂ = field with the shield …(1)
Step 1 — the same ratio for the magnetic field:
SE = 20 log₁₀(H₁/H₂) dB …(2)
Step 2 — sign convention:
E₂ < E₁ ⇒ E₁/E₂ > 1 ⇒ SE > 0 dB; SE = 0 dB means no shielding at all …(3)
Worked problem · Theory recap
Explain shielding effectiveness of a conducting sheet. Describe absorption loss, reflection loss and the multiple-reflection correction with their expressions, and explain how frequency, conductivity, permeability and apertures affect the shielding.
Setup — for a conducting sheet, SE = A + R + M.
Absorption: A = 8.686 t/δ dB inside the metal …(1)
Reflection: R = 20 log₁₀(|η₀|/4|ηₙ|) at the two faces …(2)
Multiple reflection: M = 20 log₁₀|1 − e−2t/δ| dB, negative, negligible when t ≫ δ …(3)
Step 1 — frequency and material trends:
δ = 1/√(πfµσ) ⇒ higher f, σ, µ shrink δ ⇒ A = 8.686 t/δ rises …(4)
|ηₙ| = √(ωµ/σ) ∝ √f ⇒ R = 20 log₁₀(|η₀|/4|ηₙ|) falls with f …(5)
Step 2 — apertures:
A slot or seam leaks when its longest dimension approaches λ/2 ⇒ SE collapses there regardless of t …(6)
Worked problem · Copper sheet, 0.5 mm, 1 MHz
A copper sheet (σ = 5.8×107 S/m, µr = 1) of thickness 0.5 mm shields a plane wave at 1 MHz. Calculate the skin depth, absorption loss, reflection loss and total shielding effectiveness. Take η0 = 377 Ω and neglect multiple reflections.
Setup — σ = 5.8×10⁷ S/m, µŖ = 1, t = 0.5 mm, f = 1 MHz, η₀ = 377 Ω. Find δ, A, R and SE.
ω = 2π × 1×10⁶ = 6.283×10⁶ rad/s; µ = 4π×10⁻⁷ = 1.257×10⁻⁶ H/m …(1)
Step 1 — skin depth:
πfµσ = 3.142×10⁶ × 1.257×10⁻⁶ × 5.8×10⁷ = 3.948 × 5.8×10⁷ = 2.290×10⁸ …(2)
δ = 1/√(2.290×10⁸) = 1/(1.513×10⁴) = 6.61×10⁻⁵ m = 0.066 mm …(3)
Step 2 — absorption loss:
t/δ = 0.5/0.0661 = 7.57 …(4)
A = 8.686 × 7.57 = 65.7 dB …(5)
Step 3 — intrinsic impedance of the metal:
ωµ/σ = (6.283×10⁶ × 1.257×10⁻⁶)/5.8×10⁷ = 7.898/5.8×10⁷ = 1.362×10⁻⁷ …(6)
|ηₙ| = √(1.362×10⁻⁷) = 3.69×10⁻⁴ Ω …(7)
Step 4 — reflection loss:
|η₀|/(4|ηₙ|) = 377/(4 × 3.69×10⁻⁴) = 377/1.476×10⁻³ = 2.55×10⁵ …(8)
R = 20 log₁₀(2.55×10⁵) = 20 × 5.407 = 108.1 dB …(9)
Step 5 — total:
SE = A + R = 65.7 + 108.1 = 173.9 dB (M ≈ 0 since t/δ = 7.57 ≫ 1) …(10)
✓ verified
Worked problem · 1 mm aluminium at two frequencies
A 1 mm aluminium sheet (σ = 3.5×107 S/m, µr = 1) is used as a plane-wave shield. (i) Calculate the skin depth, absorption loss, reflection loss and shielding effectiveness at 10 kHz and at 1 MHz (η0 = 377 Ω, neglect multiple reflections). (ii) Analyze how each loss term changes with frequency. (iii) Find the minimum thickness for 40 dB absorption loss at 10 kHz.
Setup — σ = 3.5×10⁷ S/m, µŖ = 1, t = 1 mm, η₀ = 377 Ω; evaluate at 10 kHz and 1 MHz.
µ = 4π×10⁻⁷ = 1.257×10⁻⁶ H/m …(1)
Step 1 — skin depth at 10 kHz:
πfµσ = 3.142×10⁴ × 1.257×10⁻⁶ × 3.5×10⁷ = 3.948×10⁻² × 3.5×10⁷ = 1.382×10⁶ …(2)
δ = 1/√(1.382×10⁶) = 1/(1.176×10³) = 8.51×10⁻⁴ m = 0.851 mm …(3)
Step 2 — absorption and reflection at 10 kHz:
t/δ = 1/0.851 = 1.18 ⇒ A = 8.686 × 1.18 = 10.2 dB …(4)
ωµ/σ = (6.283×10⁴ × 1.257×10⁻⁶)/3.5×10⁷ = 7.898×10⁻²/3.5×10⁷ = 2.256×10⁻⁹ …(5)
|ηₙ| = √(2.256×10⁻⁹) = 4.75×10⁻⁵ Ω …(6)
R = 20 log₁₀(377/(4 × 4.75×10⁻⁵)) = 20 log₁₀(1.984×10⁶) = 20 × 6.298 = 126.0 dB …(7)
SE = 10.2 + 126.0 = 136.2 dB …(8)
Step 3 — at 1 MHz (f × 100):
δ ∝ 1/√f ⇒ δ = 0.851/10 = 0.085 mm …(9)
t/δ = 1/0.0851 = 11.75 ⇒ A = 8.686 × 11.75 = 102.1 dB …(10)
|ηₙ| ∝ √f ⇒ |ηₙ| = 4.75×10⁻⁵ × 10 = 4.75×10⁻⁴ Ω …(11)
R = 20 log₁₀(377/(4 × 4.75×10⁻⁴)) = 20 log₁₀(1.984×10⁵) = 20 × 5.298 = 106.0 dB …(12)
SE = 102.1 + 106.0 = 208.1 dB …(13)
✓ verifiedStep 4 — frequency trend:
δ ∝ 1/√f: 10 kHz → 1 MHz (×100) divides δ by 10 and multiplies A by 10 (10.2 → 102 dB) …(14)
|ηₙ| ∝ √f ⇒ R falls by 20 dB (126 → 106 dB) …(15)
Net SE still rises because A dominates for a thick shield …(16)
Step 5 — thickness for A = 40 dB at 10 kHz:
t = (40/8.686) × δ = 4.61 × 0.851 mm = 3.92 mm …(17)
✓ verified

16Formula sheet — everything on one screen

QuantityFormulaNotes
Propagation constantγ = α + jβ = √[(R+jωL)(G+jωC)]per m
Characteristic impedanceZ₀ = √[(R+jωL)/(G+jωC)]Z₀ = V⁺/I⁺
Losslessα = 0 · β = ω√(LC) · Z₀ = √(L/C) · vₖ = 1/√(LC)R = G = 0
Distortionlessα = √(RG) · β = ω√(LC) · Z₀ = √(L/C)if R/L = G/C
Low-loss αα ≈ R/(2Z₀) + GZ₀/2β ≈ ω√(LC)
Wavelength / velocityλ = 2π/β · vₖ = ω/β = fλ1 Np = 8.686 dB
Coax L, CL = 2×10⁻⁷ ln(b/a) · C = 55.6εŖ/ln(b/a) pF/mair line: vₖ = c/√εŖ
General ZₖₙZ₀(Zₗ + Z₀tanhγℓ)/(Z₀ + Zₗtanhγℓ)lossless: tan βℓ
λ/4 lineZₖₙ = Z₀²/Zₗmatch: Z₀′ = √(ZₖₙZₗ)
Short / open linejZ₀tanβℓ / −jZ₀cotβℓλ/2 repeats the load
Reflection coefficientΓₗ = (Zₗ−Z₀)/(Zₗ+Z₀)S = (1+|Γ|)/(1−|Γ|)
Return lossRL = −20 log₁₀|Γ| dBpower ratio 10log(Pₖₙ/PŖₖₜ)
Line powerP = (|V₀⁺|²/2Z₀)(1−|Γ|²)lossless, anywhere
Line identitiesLC = με · G/C = σ/εhomogeneous line
Efficiency (matched)η = e−2αℓ × 100%att dB = αℓ×8.686
dB refsdBµV = 20log(V/1µV) · dBµA = 20log(I/1µA)across 50 Ω
Skin depthδ = 1/√(πfμσ)μ = µŖµ₀
Absorption lossA = 8.686 t/δ dBplane wave in sheet
Reflection lossR = 20 log₁₀(377/4|ηₙ|) · |ηₙ| = √(ωμ/σ)far field
Shielding effectivenessSE = A + R + M (≈ A + R)SE = 20log(E without/with)