Unguided vs guided. A uniform plane wave in an unbounded medium is
unguided — the EM energy spreads over the whole space, which is exactly what
radio/TV broadcasting wants. To deliver power or information efficiently from a
source to a chosen load we instead use guided structures — transmission lines and
waveguides — which direct the energy along a defined path. Transmission lines carry power
distribution at low frequencies and signals in communications at high frequencies;
twisted-pair and coax are the backbones of Ethernet and other computer networks.
Definition. A transmission line is two or more parallel conductors used to
connect a source (generator, transmitter, oscillator) to a load (antenna, factory,
oscilloscope). The three classic examples are the coaxial cable (lab instruments,
TV down-leads), the two-wire line (open-wire or twisted pair) and the
microstrip line (metal strips on a dielectric substrate — the wiring of every PCB
and integrated circuit). We analyse lines with circuit theory (easier than full
field theory) precisely because a TEM wave lets us replace fields E, H by voltage and
current.
Cross-sections of the three classic lines. Credit: redrawn
(after Sadiku fig. 11.1).
The TEM wave on a line. Close the switch of a coax feeding a load: the inner
conductor goes positive with respect to the outer one, so E points radially outward;
by Ampère's law the current is encircled by H. The Poynting vector
S = E × H points along the line — so the disturbance travels as a
transverse electromagnetic (TEM) wave (E ⊥ H ⊥ direction of travel; it
is a nonuniform plane wave). Two TEM properties do all the work in this unit:
V is uniquely related to E and I to H, so circuit quantities replace field quantities.
(a) Generator–coax–load circuit; (b) cross-section
showing radial E, circumferential H and S along the line. Credit: redrawn (after Sadiku
fig. 11.4).
V = −∫ E · dℓ
I = ∧ H · dℓ (TEM line: fields ↔ circuit
quantities)
This unique V↔E, I↔H mapping is why the whole unit can be
done with R, L, G, C instead of Maxwell's equations.
2Primary constants R, L, G, C
The four line parameters. A line is described by four quantities defined
per unit length: R — resistance of the two conductors (Ω/m, series
loss in copper); L — inductance (H/m, from flux linkage between the conductors);
G — conductance (S/m, leakage through the dielectric); C — capacitance
(F/m, charge storage between the conductors). These are the primary constants;
γ, Z₀, α, β derived from them are the secondary constants.
Worked problem · The four primary constants
Define the four primary constants (R, L, G, C) of a transmission line and state the unit of each.
Setup — the line is described per unit length, so each primary constant is a rate, not a lump.
R = series resistance of both conductors per metre → Ω/m …(1)
L = series inductance per metre → H/m …(2)
G = shunt (dielectric leakage) conductance per metre → S/m …(3)
All four are distributed quantities (per metre), so the line is a chain of RΔz, LΔz, GΔz, CΔz slices — not one lumped RLC network.
Distributed view: every Δz slice carries the same
RΔz, LΔz, GΔz, CΔz. Credit: redrawn (after Sadiku fig. 11.3).
Why "distributed" matters. The parameters are
not lumped at one point — they are spread uniformly along the whole length. A
lumped model works only while the line is electrically short. Once the line length is
comparable to the wavelength, the phase of the signal changes appreciably along the
line, so we must treat R, L, G, C as a continuum and solve differential equations —
that is the telegrapher's model of section 3.
Feature
Lumped circuit
Distributed
(transmission line)
Elements
concentrated at a single point
spread along the entire
line, functions of position
Valid when
physical dimensions ≪ λ
length comparable
to (or larger than) λ
Analysis
ordinary algebra / Kirchhoff laws
differential equations
(∂V/∂z, ∂I/∂z)
Examples
RC network, resistor on a board
power line, coax, PCB
trace at high f
For each line of length ℓ: Lℓ = μℓ,
Cℓ = εℓ ⇒ LC = με
and G/C = σ/ε
Two dimensionally-consistent identities for a homogeneous line — handy
as an exam sanity check.
High-frequency L and C of real lines (Table 11.1) — these are what the coax
numericals use:
Line
L (H/m)
C (F/m)
Coax (inner a, outer b)
(μ/2π) ln(b/a)
2πε / ln(b/a)
Two-wire (radius a, spacing d)
(μ/π) acosh(d/2a)
πε / acosh(d/2a)
Coax shortcuts: L = 2×10⁻⁷ ln(b/a) H/m
(µ = µ₀), C = 55.6 εₙ/ln(b/a) pF/m
L = (µ₀/2π)ln(b/a) with µ₀/2π = 2×10⁻⁷;
C = 2π(8.854×10⁻¹²εŖ)/ln(b/a).
Worked problem · Coaxial cable numbers
A coaxial cable has inner conductor radius 0.45 mm, outer conductor inner radius 1.47 mm and a dielectric with εr = 2.25. Assuming a lossless line, calculate L and C per metre, Z0, the phase velocity and the time delay over a 30 m length.
Setup — a = 0.45 mm, b = 1.47 mm, εŖ = 2.25, lossless line, length 30 m. Find L, C, Z₀, vₖ and the delay.
Setup. Take an elemental slice of length Δz of the two-conductor line.
Over this slice the distributed constants become lumped: series RΔz and LΔz in
the conductors, shunt GΔz and CΔz between them. Apply Kirchhoff's laws to this
slice, then shrink Δz → 0 to get differential equations. This is the classic textbook derivation.
Worked problem · Why the distributed model?
Draw the equivalent circuit of a differential length Δz of a two-conductor transmission line. Explain why a distributed-parameter model is required instead of a lumped model when the line length is comparable to the wavelength.
A lumped circuit is valid only while dimensions ≪ λ. When the line length is comparable to the wavelength, V and I change appreciably over the line's length, so the line is modelled as a chain of differential slices (each RΔz, LΔz, GΔz, CΔz) and described by differential equations — not by a single RLC network.
example: a 1 m line at 50 Hz (λ = c/f = 3×10⁸/50 = 6000 km) gives l/λ = 1.7×10⁻⁷ → lumped; the same line at 1 GHz (λ = 30 cm) gives l/λ = 3.3 → distributed. The circuit, not the wire, decides.
Equivalent circuit of a differential length Δz. Credit:
redrawn (after Sadiku fig. 11.5).
Derivation path (exam-writable) 1. KVL around the loop: V(z,t) − RΔz I − LΔz
∂I/∂t − V(z+Δz, t) = 0
2. ÷ Δz, Δz → 0: ∂V/∂z = −(R I + L
∂I/∂t) 3. KCL at the top node: I(z,t) − GΔz V − CΔz
∂V/∂t − I(z+Δz, t) = 0
4. Δz → 0: ∂I/∂z = −(G V + C
∂V/∂t) these two are the telegrapher's equations (time
domain)
Phasor form and the wave equation. With harmonic excitation
V(z,t) = Re[Vₙ(z)ejωt], the pair becomes
dVₙ/dz = −(R + jωL)Iₙ and dIₙ/dz = −(G + jωC)Vₙ.
Differentiate one and substitute the other: both Vₙ and Iₙ obey the same
second-order wave equation d²Vₙ/dz² = γ²Vₙ with
γ = propagation constant; Z₀ = characteristic impedance.
Both come straight from the primary constants — memorise these two, every special case
follows from them.
General solution. The wave equation's solution is a forward wave (travelling
+z, decaying) plus a backward wave (travelling −z):
In time domain: V(z,t) = V₀ e−αz
cos(ωt − βz) — a cosine riding on a decaying envelope, sketched below.
Snapshot of the forward wave: cosine phase inside an
exponentially decaying envelope. Credit: redrawn (after Sadiku fig. 11.7 context).
4α, β, λ, vₖ, Z₀ — meaning + numbers
Physical significance. Writing γ = α + jβ:
α — attenuation constant (Np/m or dB/m): the amplitude of V and I decays
as e−αz; after 1 m the wave is smaller by a factor
e−α. (8.686 dB = 1 Np.)
β — phase constant (rad/m): the phase shift accumulated per metre; it sets
how fast the phase front moves.
λ — wavelength: distance the wave travels to repeat its phase:
λ = 2π/β = vₖ/f.
vₖ — phase velocity: vₖ = ω/β = fλ, the speed of the
phase front (not necessarily the energy speed on a lossy line).
Z₀: ratio of forward voltage to forward current at any point
(Z₀ = V₀⁺/I₀⁺ = −V₀⁻/I₀⁻);
it equals the input impedance of an infinitely long line — the "load the line itself
presents".
λ = 2π/β
vₖ = ω/β = fλ
Z₀ = √[(R+jωL)/(G+jωC)]
1 Np = 8.686 dB — used every time a problem asks "attenuation in
dB".
Worked problem · Definitions
Define characteristic impedance and propagation constant of a transmission line. Write their expressions in terms of R, L, G and C.
Setup — a uniform line of primary constants R, L, G, C per metre carries the forward wave V⁺e−γz, I⁺e−γz.
Z₀ ≡ V⁺/I⁺ = √[(R + jωL)/(G + jωC)] …(1)
γ ≡ α + jβ = √[(R + jωL)(G + jωC)] …(2)
Step 1 — where the ratio comes from:
Series drop per metre = (R + jωL)I⁺; shunt current per metre = (G + jωC)V⁺ ⇒ V⁺/I⁺ = (R + jωL)/γ = γ/(G + jωC) …(3)
Step 2 — eliminate γ:
Multiply the two forms in (3): (V⁺/I⁺)² = (R + jωL)/(G + jωC) ⇒ Z₀ = √[(R + jωL)/(G + jωC)] …(4)
Step 3 — result:
Z₀ in Ω (complex unless the line is lossless or distortionless); γ in m⁻¹, with α in Np/m and β in rad/m.
Worked problem · Physical significance
Explain the physical significance of the attenuation constant, phase constant, wavelength and phase velocity of a transmission line, with the relevant expressions.
Setup — write the wave as e−αze−jβz, so α and β act on amplitude and phase separately.
α = 0 and β = ω√(LC) ⇒ vₖ = ω/β = 1/√(LC), independent of f …(5)
Every frequency component travels at the same vₖ ⇒ no dispersion, so the line does not distort the signal.
Worked problem · Open-wire line at 800 Hz
An open-wire line has R = 4 Ω/km, L = 3 mH/km, G = 0.5 µS/km and C = 0.008 µF/km. At 800 Hz, calculate characteristic impedance, propagation constant, phase velocity and wavelength.
Setup — R = 4 Ω/km, L = 3 mH/km, G = 0.5 µS/km, C = 0.008 µF/km, f = 800 Hz. Find Z₀, γ, vₖ, λ.
Worked problem · Reverse problem — recover R, L, G, C from Z₀ and
γ
At ω = 5000 rad/s a line has Z0 = 397.6∠−35.64° Ω and γ = 0.07953∠54.07° per km. Determine the primary constants R, L, G and C per km, the phase velocity and the wavelength.
✓ verified(G comes out 1.01 µS/km from the rounded data — the intended answer is 1 µS/km.)
5Lossless, distortionless, low-loss
A. Lossless line (R = 0 = G). Superconducting lines (or a good approximation
over short distances) have no series resistance and no leakage. Substituting R = G = 0
into the general γ and Z₀:
B. Distortionless line (R/L = G/C) — derivation. Distortion means
different frequency components arrive with different attenuation and delay — the
envelope smears. Heaviside's condition removes it. Start from
γ² = (R + jωL)(G + jωC) = RG + jω(RC + LG) − ω²LC.
This becomes a perfect square when RC = LG:
All frequencies attenuate equally and travel at the same speed ⇒
no distortion. This is why old telephone lines were "loaded" with extra inductance
(section 9).
C. Low-loss line. Real RF lines (coax) are not exactly lossless but
R ≪ ωL and G ≪ ωC. Expanding the general expressions to first
order:
α ≈ R/(2Z₀) + G Z₀/2 ·
β ≈ ω√(LC) ·
Z₀ ≈ √(L/C)
Good to ~1% when R≪ωL — this is the working formula for the
B8-type numerical.
Worked problem · Distortionless condition
State the condition for a distortionless line. Write the expressions for α, β and Z0 under this condition.
Setup — require the same attenuation and the same velocity at every frequency.
Condition: R/L = G/C …(1)
Step 1 — factor the series impedance:
R + jωL = L(R/L + jω) = L(k + jω), with k ≡ R/L …(2)
Explain the characteristics of a lossless transmission line. Obtain its α, β, Z0 and phase velocity from the general expressions and show that Z0 is purely real.
Setup — set R = 0 and G = 0 in the general expressions.
γ = α + jβ ⇒ α = 0 (no attenuation) and β = ω√(LC) …(3)
Step 2 — phase velocity:
vₖ = ω/β = ω/(ω√(LC)) = 1/√(LC) = 1/√(µε) …(4)
Step 3 — Z₀ is real:
Z₀² = L/C is a positive real number ⇒ Z₀ = R₀ + j0, purely real …(5)
Case
γ = α + jβ
Z₀
vₖ
General (lossy)
√[(R+jωL)(G+jωC)]
√[(R+jωL)/(G+jωC)]
ω/β
Lossless
0 + jω√(LC)
√(L/C) = R₀
1/√(LC)
Distortionless
√(RG) + jω√(LC)
√(L/C) = R₀
1/√(LC)
Lossless vs distortionless (common trap). Both have real
Z₀ = √(L/C) and β = ω√(LC), but the lossless line has
α = 0 while the distortionless line only requires α = √(RG) to be
frequency-independent. A lossless line is automatically distortionless; a
distortionless line is generally lossy — telephone lines are deliberately loaded
to become distortionless, accepting some loss.
Worked problem · Design a distortionless line
A distortionless line is required to have Z0 = 75 Ω, α = 0.03 Np/m and a phase velocity of 0.7c. Determine R, L, G and C per metre, and the wavelength at 150 MHz.
Setup — Z₀ = 75 Ω, α = 0.03 Np/m, vₖ = 0.7c, f = 150 MHz. Find R, L, G, C and λ.
A low-loss line has R = 0.1 Ω/m, L = 0.2 µH/m, G = 10 µS/m and C = 80 pF/m. At 500 MHz, calculate Z0, α, β, the wavelength, the phase velocity and the total attenuation in dB over 50 m.
Setup — R = 0.1 Ω/m, L = 0.2 µH/m, G = 10 µS/m, C = 80 pF/m, f = 500 MHz, ℓ = 50 m. Find Z₀, α, β, λ, vₖ and the loss in dB.
λ = 2π/β = 6.283/12.57 = 0.5 m; vₖ = ω/β = 3.1416×10⁹/12.57 = 2.5×10⁸ m/s …(11)
Step 5 — loss over 50 m:
αℓ = 1.25×10⁻³ × 50 = 0.0625 Np …(12)
Loss = 0.0625 × 8.686 = 0.54 dB …(13)
✓ verified
6Input impedance Zₖₙ
Why it matters. Everything the source "sees" is the input impedance of the
line-plus-load combination. Zₖₙ depends on the load, on Z₀, and on the
electrical length βℓ of the line — which is why the same antenna can
look completely different through different cable lengths.
(a) Line of length ℓ terminated in Zₗ; (b) the
same line replaced by its input impedance. Credit: redrawn (after Sadiku fig. 11.6).
Derivation route (exam-writable). Write the general solution at z = ℓ
(Vₗ = V(ℓ), Iₗ = I(ℓ)), solve for the wave amplitudes
V₀⁺ = ½(Vₗ + Z₀Iₗ)eγℓ and
V₀⁻ = ½(Vₗ − Z₀Iₗ)e−γℓ,
then form V(z)/I(z) at z = 0. Collecting terms with the identities
cosh γℓ = (eγℓ + e−γℓ)/2 and
sinh γℓ = (eγℓ − e−γℓ)/2:
βℓ is called the electrical length (in degrees or
radians). Every special-length result of section 8 drops out of this one formula.
7Reflection coefficient, SWR, return loss, power
Mismatch creates a reflected wave. If the load is not Z₀, the backward
wave is not zero and the line carries standing waves. The whole phenomenon is
governed by the reflection coefficient at the load:
Three standard loads. Put Zₗ = 0 (short), Zₗ → ∞ (open)
and Zₗ = Z₀ (matched) into the lossless Zₖₙ formula:
Load
Zₖₙ
Γₗ
S
Comment
Short (Zₗ = 0)
jZ₀ tan βℓ
−1
∞
pure reactance; βℓ < 90° looks inductive
Open (Zₗ → ∞)
−jZ₀ cot βℓ
+1
∞
dual of the short; βℓ < 90° looks
capacitive
Matched (Zₗ = Z₀)
Z₀
0
1
no reflection — whole wave absorbed, max power transfer
Three standard lengths (for a lossless line, any load): setting
βℓ = π/4, π/2 and π/4×½ in the Zₖₙ
formula gives the results every exam reuses:
The λ/8, λ/4 and λ/2 line results. Credit:
original drawing for these notes (after Sadiku sec. 11.5).
λ/4: Zₖₙ = Z₀²/Zₗ —
impedance inverter. Matching trick: insert a quarter-wave section with
Z₀′ = √(Zₖₙ Zₗ) between a Zₖₙ line
and a resistive load Zₗ. A shorted λ/4 stub looks open, and vice versa.
λ/2: Zₖₙ = Zₗ — the load repeats itself (1:1
transformer). λ/8: |Zₖₙ| = R₀ for any resistive load.
9Big line problems (100 km line, cable loading)
Two Part-C classics that combine everything from sections 3–5: a long lossy line
worked end-to-end, and a telephone cable that fails the Heaviside test and has to be
loaded back into shape.
Worked problem · 100 km line, matched load
A 100 km line has R = 6 Ω/km, L = 2.2 mH/km, G = 0.05 µS/km and C = 0.005 µF/km. It is terminated in its characteristic impedance and fed with 10 V (rms) at 1 kHz. Calculate Z0, γ, the sending-end current, the receiving-end voltage and current, the line attenuation in dB and the transmission efficiency.
Setup — R = 6 Ω/km, L = 2.2 mH/km, G = 0.05 µS/km, C = 0.005 µF/km; Vₙ = 10 V rms at 1 kHz; ℓ = 100 km, terminated in Z₀. Find Z₀, γ, Iₙ, VŖ, IŖ, attenuation in dB and efficiency.
Because the line is matched, V/I = Z₀ everywhere, so the power factor is the same at both ends and η reduces to e−2αℓ. A 100 km line at 1 kHz is brutally lossy — this is why telephone systems used repeaters and loading.
Worked problem · Distortion check + inductive loading
A cable has R = 10 Ω/km, L = 1 mH/km, G = 10 µS/km and C = 0.05 µF/km. (i) Check whether it is distortionless. (ii) Calculate α and the phase velocity at 500 Hz, 1 kHz and 3 kHz and comment on the distortion. (iii) Find the inductance to be added per km to make it distortionless, and the resulting Z0, α and phase velocity.
Setup — R = 10 Ω/km, L = 1 mH/km, G = 10 µS/km, C = 0.05 µF/km. (i) distortionless? (ii) α and vₖ at 500 Hz, 1 kHz, 3 kHz; (iii) loading.
R/L = 10/1×10⁻³ = 1.0×10⁴ …(1)
G/C = 10×10⁻⁶/0.05×10⁻⁶ = 200 …(2)
1.0×10⁴ ≠ 200 ⇒ not distortionless …(3)
Step 1 — α and vₖ versus frequency (γ = √(ZY), vₖ = ω/β):
f
α (Np/km)
β (rad/km)
vₖ (km/s)
500 Hz
0.0251
0.0320
9.83×10⁴
1 kHz
0.0303
0.0528
1.19×10⁵
3 kHz
0.0350
0.1374
1.37×10⁵
Step 1 — read the table:
α rises 0.0251 → 0.0303 → 0.0350 Np/km and vₖ rises 9.83×10⁴ → 1.19×10⁵ → 1.37×10⁵ km/s as f goes 500 Hz → 1 kHz → 3 kHz …(1)
High-frequency speech components arrive later and weaker than low ones ⇒ the line distorts speech …(2)
α rises and vₖ rises with frequency
⇒ high-frequency speech components arrive later and weaker than low ones —
the line distorts speech. (iii) Loading: require R/L′ = G/C ⇒ L′ = RC/G =
10 × 0.05×10⁻⁶ / 10×10⁻⁶ = 0.05 H/km. Add ΔL = 50 − 1 = 49 mH/km. After loading: Z₀ = √(L′/C) = √(0.05/5×10⁻⁸) =
1000 Ω · α = √(RG) = √(10×10⁻ⁱ) =
0.01 Np/km (frequency-independent) · vₖ = 1/√(L′C) =
2×10⁴ km/s (frequency-independent) ✓
verified
10EMI vs EMC, classification, sources
The problem and the solution.EMI (electromagnetic interference) is the
degradation in the performance of a device due to the fields making up the
electromagnetic environment — unwanted voltages or currents that disturb proper
operation. EMC (electromagnetic compatibility) is the solution: a device
functions satisfactorily in its environment without introducing intolerable
disturbances into that environment. EMC is achieved by proven design techniques
(grounding, shielding, filtering) rather than by luck.
Worked problem · EMI vs EMC with examples
Distinguish between electromagnetic interference (EMI) and electromagnetic compatibility (EMC), with one example of each.
Setup — EMI is an event; EMC is a property of the finished design.
EMI: unwanted EM energy couples from a source into a victim and degrades its performance …(1)
EMC: the device both emits below the limit and survives the immunity level, in the same environment …(2)
Step 1 — example of EMI:
A personal computer radiates broadband noise → picked up by a nearby FM receiver (ghosting on a TV picture, speech interruption on a police radio) …(3)
Step 2 — example of EMC by design:
Shield a switching supply inside a grounded metal enclosure ⇒ the supply and the radio next to it both keep working …(4)
So EMI is the failure; EMC is the state reached when the emission and immunity margins are both met.
Classification. The cause may be within the system (intrasystem EMI —
e.g. a motor inside the same cabinet noise-ing up its own amplifier) or from
outside (intersystem EMI — e.g. a broadcast transmitter hitting a hi-fi). The source
of EMI is the emitter; the disturbed device is the susceptor (victim).
Both kinds are controllable by the design engineer through grounding/wiring,
shielding and filtering.
Typical intersystem EMI scene — every emitter (E) threatens
susceptible equipment (S) nearby. Credit: reused from lecture deck, slide 61 (Sadiku
fig. 13.5).
Sources of EMI. Three families: (1) intrinsic noise — random
fluctuations inside physical systems (thermal noise, shot noise); (2) man-made
sources — motors, switches, computers/digital electronics, radio transmitters, power
lines; (3) natural disturbances — lightning, sunspots. Distinguish noise
from interference: interference is the undesirable effect of noise when it
causes improper operation — noise itself cannot be eliminated, but interference
can be controlled.
11Source–path–victim + coupling mechanisms
The three-element model. Every EMI problem needs all three of a
source, a coupling path and a victim — remove any one and the
problem disappears. This gives the engineer exactly three places to attack: quiet the
source, block the path, or harden the victim.
The universal EMI block model. Credit: original drawing for
these notes (after Ott, Electromagnetic Compatibility Engineering).
Four coupling mechanisms. The noise travels from source to victim by
conduction, by electric fields, by magnetic fields, or through space as a radiated wave
— recognising which one dominates decides which fix works.
The four coupling mechanisms. Credit: original drawings for
these notes (after Ott ch. 2).
Worked problem · Model + four mechanisms with examples
Explain the source, coupling path and victim model of an EMI problem with a neat block diagram. Describe the four coupling mechanisms (conductive, capacitive, inductive and radiative) with one example each.
Setup — every EMI problem is a source → coupling path → victim chain.
Source (e.g. a switching transistor) → coupling path → victim (e.g. an amplifier) …(1)
Step 1 — conductive coupling:
Noise current shares a conductor: v = i·Z_common ⇒ the i·Z drop of one circuit appears in the other (two circuits sharing a ground wire) …(2)
Step 2 — capacitive coupling:
Stray capacitance injects i = C·dV/dt ⇒ a power cable running next to a signal cable …(3)
Step 3 — inductive coupling:
Mutual inductance couples di/dt: v = M·di/dt ⇒ the field of a relay-coil loop induces voltage in a nearby signal loop …(4)
Step 4 — radiative coupling:
Source and victim act as antennas ⇒ a handheld transmitter's field is picked up by a receiver's cable …(5)
12Conducted vs radiated, emission & immunity, the 4 tests
Two origins of EMI.Conducted emissions are noise voltages/currents
carried along metallic paths — typically out of the equipment's power cord onto the
common power network, where they bother everything else plugged in. Radiated
emissions are the E and/or H fields the device radiates through space, picked up by
other electronics. Every EMC standard regulates both, because every product is both a
transmitter and a receiver of junk.
Conducted (via the power cord and mains) vs radiated (through
space) emissions from one device. Credit: redrawn (after Sadiku fig. 13.24).
Emission vs susceptibility. EMC has two aspects. Emission is the
interference-causing potential of a product — controlling it limits the EM environment
everyone else must live in. Susceptibility is the capability of a device to
respond to unwanted EM energy; its opposite is immunity — the maximum EM
environment in which the equipment still works to spec, with a defined safety margin.
The four test categories. Compliance labs run four kinds of tests,
two on what leaks out, two on what the device can stand:
Test
Measures
Conducted emission
noise voltage/current the device pushes onto
its power/signal lines (LISN + receiver, 150 kHz–30 MHz)
Radiated emission
field strength radiated by the device, measured
with calibrated antennas on an open-area site or in a chamber (30 MHz–1 GHz+)
Conducted susceptibility
does the device still work when RF/burst
noise is deliberately injected onto its power and signal lines?
Radiated susceptibility
does it still work inside a known
radiated field (antenna or cell in a chamber)?
Worked problem · Sources + the four tests
List the natural and man-made sources of EMI. Name the four categories of EMI/EMC tests (conducted emission, radiated emission, conducted susceptibility, radiated susceptibility) and state what each one measures.
Setup — classify the sources, then classify the four tests by what each one measures.
Conducted susceptibility: survives injected line noise …(5)
Radiated susceptibility: survives an applied field …(6)
Worked problem · Susceptibility + microcontroller case
Explain conducted and radiated susceptibility (immunity) and how they are tested. A microcontroller board resets whenever a nearby relay switches or a mobile phone is held close to it. Analyze the likely coupling path in each case and propose suitable measures (filtering, shielding, grounding, layout) to make the board compliant.
Setup — immunity is tested by injecting the disturbance and watching for malfunction.
Conducted susceptibility: RF, fast transients and surges injected through coupling networks onto the mains and I/O lines while the unit is monitored …(1)
Radiated susceptibility: the board is exposed to a calibrated field from an antenna in a screened chamber …(2)
Step 1 — case 1, relay switching:
Coil interrupt gives a fast di/dt burst: v = M·di/dt couples inductively, the shared ground/supply couples conductively, and the spark also radiates …(3)
Fixes: flyback diode/snubber across the coil; separate ground returns; decoupling caps at the MCU; RC filter + Schmitt on RESET; short reset traces away from power wiring …(4)
Step 2 — case 2, mobile phone held close:
GSM burst at ~900/1800 MHz is a strong radiated RF field, demodulated by nonlinear junctions or picked up on cables/loops, upsetting the reset/power rails …(5)
Burst duty cycle 1/8 ⇒ peak-to-average = 10 log₁₀8 = 10 × 0.903 = 9.0 dB, so the peak field is ~9 dB above the average …(6)
Fixes: local RF shielding can, ferrites on cables, shorter/grounded I/O, ground plane, filtering on reset and supply, software watchdog …(7)
Together: filter + shield + ground + layout.
13Conducted emission, CM/DM currents, the LISN
Conducted emission testing. The equipment (EUT) is plugged to a clean
mains through a Line Impedance Stabilisation Network (LISN) — an "artificial
mains". It does three jobs: (1) presents the EUT a standard, stable 50 Ω RF
impedance so measurements are repeatable; (2) couples the noise on L and N to
a 50-Ω test receiver (read in dBµV); (3) isolates the EUT from mains
noise coming in from the wall.
(a) LISN block schematic; (b) differential-mode vs
common-mode noise currents. Credit: original drawing for these notes (after CISPR 16 /
Ott ch. 11).
Two modes of conducted noise.Differential mode (DM): current goes down
one line and returns on the other — the "normal" circuit loop; filter with X-caps and
series chokes. Common mode (CM): equal currents flow the same direction on
both lines and return through stray capacitance/ground — parasitic leakage, usually the
bigger offender at high frequency; filter with Y-caps to earth and common-mode chokes.
Worked problem · SMPS noise vs the limit
A switched-mode power supply produces a conducted noise voltage of 2 mV across the 50 Ω port of a LISN. Express the noise in dBµV and the noise current in dBµA. If the limit is 56 dBµV, find by how much it is exceeded and the minimum filter insertion loss needed for a 6 dB margin.
Setup — V = 2 mV across the 50 Ω LISN port, limit 56 dBµV. Find dBµV, dBµA, the excess and the insertion loss for a 6 dB margin.
V/1 µV = 2×10⁻³/1×10⁻⁶ = 2000 …(1)
Step 1 — noise voltage in dBµV:
20 log₁₀(2000) = 20 × 3.301 = 66.02 dBµV …(2)
Step 2 — noise current and dBµA:
I = V/R = 2×10⁻³/50 = 4.0×10⁻⁵ A = 40 µA …(3)
20 log₁₀(40) = 20 × 1.602 = 32.04 dBµA …(4)
Step 3 — excess over the limit:
66.02 − 56 = 10.02 dB over the limit …(5)
Step 4 — insertion loss for a 6 dB margin:
IL ≥ 10.02 + 6 = 16.02 dB …(6)
✓ verified
14Grounding, shielding, filtering
The three suppression tools. Almost every intrasystem EMC fix reduces to one
of three moves: give junk currents a path to earth, keep radiated energy where it
belongs, or filter what is left on the wires. They are complementary — good grounding
reduces how much shielding and filtering you need, and good shielding reduces how much
filtering you need.
The three techniques at a glance. Credit: original drawing
for these notes.
Grounding provides a conducting path between the equipment and ground.
"Ground" is just a reference point; an ideal ground plane is a zero-potential,
zero-impedance body used as the reference for all signals, into which undesired current
can be drained and eliminated.
Shielding confines radiated energy to a region — or keeps it out of one.
Shields are partitions, boxes, cable braids; solid, screened (mesh) or braid types all
work by reflecting and absorbing the field.
Filtering: a filter is a network of R, L, C that passes some frequencies with
little opposition while blocking others; it is the main weapon against conducted
interference — and low-pass filters are the standard choice in EMC work (noise is
usually high frequency, signal is not).
15Shielding effectiveness — skin depth, A, R, M
Definition. The shielding effectiveness of a shield is the ratio of
field strength without the shield to field strength with it, in dB:
SE = 20 log₁₀(E₁/E₂) dB (same form for H or power). A plane-wave
shield eats the wave three ways — absorption, reflection, and a multiple-reflection
correction:
SE (dB) = A + R + M A = 8.686 t/δ dB (absorption: wave decays e−t/δ
crossing thickness t)
R = 20 log₁₀(|η₀| / 4|ηₙ|) dB (reflection at
the air↔metal faces; η₀ = 377 Ω)
|ηₙ| = √(ωμ/σ) (intrinsic impedance of the good
conductor) · M ≈ 0 when t ≫ δ (rule of thumb: A > 15 dB)
δ = skin depth = 1/√(πfμσ). Multiple reflections
matter only in thin shields where the two faces "see" each other.
Plane wave → conducting sheet: reflected at the entry
face, absorbed inside, weak remainder exits; M counts internal bounces. Credit: original
drawing for these notes (after Ott ch. 6).
Skin effect: current density falls as e−x/δ
below the surface. Credit: original drawing for these notes (after Sadiku sec. 10.10
context).
What moves the numbers. Higher frequency, higher conductivity and
higher permeability all shrink δ, so A grows with f, σ, μ and
thickness — but R falls with frequency (because |ηₙ| √f grows
toward 377 Ω). For magnetic materials μŖ ≫ 1 helps absorption but hurts
reflection (ηₙ rises). Any aperture (seam, hole, ventilation slot) with a
long dimension near λ/2 leaks like an open window — seams must be conductive-gasketed
and holes kept ≪ λ/20 to keep the box shielding.
Worked problem · Definition
Define shielding effectiveness. Write its expression in dB in terms of the electric field with and without the shield.
Setup — compare the field at the same point with and without the shield.
SE = 20 log₁₀(E₁/E₂) dB, with E₁ = field without the shield and E₂ = field with the shield …(1)
Step 1 — the same ratio for the magnetic field:
SE = 20 log₁₀(H₁/H₂) dB …(2)
Step 2 — sign convention:
E₂ < E₁ ⇒ E₁/E₂ > 1 ⇒ SE > 0 dB; SE = 0 dB means no shielding at all …(3)
Worked problem · Theory recap
Explain shielding effectiveness of a conducting sheet. Describe absorption loss, reflection loss and the multiple-reflection correction with their expressions, and explain how frequency, conductivity, permeability and apertures affect the shielding.
Setup — for a conducting sheet, SE = A + R + M.
Absorption: A = 8.686 t/δ dB inside the metal …(1)
Reflection: R = 20 log₁₀(|η₀|/4|ηₙ|) at the two faces …(2)
Multiple reflection: M = 20 log₁₀|1 − e−2t/δ| dB, negative, negligible when t ≫ δ …(3)
|ηₙ| = √(ωµ/σ) ∝ √f ⇒ R = 20 log₁₀(|η₀|/4|ηₙ|) falls with f …(5)
Step 2 — apertures:
A slot or seam leaks when its longest dimension approaches λ/2 ⇒ SE collapses there regardless of t …(6)
Worked problem · Copper sheet, 0.5 mm, 1 MHz
A copper sheet (σ = 5.8×107 S/m, µr = 1) of thickness 0.5 mm shields a plane wave at 1 MHz. Calculate the skin depth, absorption loss, reflection loss and total shielding effectiveness. Take η0 = 377 Ω and neglect multiple reflections.
Setup — σ = 5.8×10⁷ S/m, µŖ = 1, t = 0.5 mm, f = 1 MHz, η₀ = 377 Ω. Find δ, A, R and SE.
R = 20 log₁₀(2.55×10⁵) = 20 × 5.407 = 108.1 dB …(9)
Step 5 — total:
SE = A + R = 65.7 + 108.1 = 173.9 dB (M ≈ 0 since t/δ = 7.57 ≫ 1) …(10)
✓ verified
Worked problem · 1 mm aluminium at two frequencies
A 1 mm aluminium sheet (σ = 3.5×107 S/m, µr = 1) is used as a plane-wave shield. (i) Calculate the skin depth, absorption loss, reflection loss and shielding effectiveness at 10 kHz and at 1 MHz (η0 = 377 Ω, neglect multiple reflections). (ii) Analyze how each loss term changes with frequency. (iii) Find the minimum thickness for 40 dB absorption loss at 10 kHz.
Setup — σ = 3.5×10⁷ S/m, µŖ = 1, t = 1 mm, η₀ = 377 Ω; evaluate at 10 kHz and 1 MHz.