COA Notes: Control Unit

Nov 19, 2026·Pranesh Mahanta·21ECC301T — Computer Organization and Architecture

Control unit design, hardwired vs microprogrammed control, and pipelining with its hazards.

Contents
  1. Basic processing unit — fetch & execute
  2. Processor organization — single-bus datapath
  3. Register transfers & gating
  4. Performing an ALU operation
  5. Fetching & storing a word from memory
  6. Execution of a complete instruction
  7. Multi-bus organization
  8. Hardwired control
  9. Microprogrammed control
  10. Control word format — shrinking microinstructions
  11. Pipelining — basic concepts
  12. Pipeline performance — and why it stalls
  13. Pipeline hazards — structural & data
  14. Instruction (control) hazards — branches & prefetch
  15. Delayed branch & branch prediction
  16. Influence on instruction sets

1Basic processing unit — fetch & execute

A program is a sequence of machine instructions; the processor fetches one instruction at a time and performs the operation it specifies. Instructions come from successive memory locations until a branch or jump is encountered.

Two phases of every instruction cycle:
Fetch phase — IR ← [[PC]]  and  PC ← [PC] + 4 (byte-addressable memory, 4-byte instructions)
Execution phase — carry out the action specified by the instruction in IR
PCMARMemory…instruction…MDRIR1234PC ← [PC] + 4address of nextinstructioninstruction loaded→ executeFetch phase: IR ← [[PC]], then PC ← [PC] + 4
Fetch phase — the four steps from PC to IR, with PC incremented by 4

The execution phase can perform one or more of these four kinds of operations (a classic Part-B list):

Worked problem
“Explain in detail about the Instruction execution in a processor”

Answer with: (1) the fetch-phase equations IR ← [[PC]], PC ← [PC] + 4 and the diagram above → (2) the execution phase → (3) the four kinds of micro-operations listed here → then continue into §3–§6 (register transfers, ALU operation, memory read/write, complete instruction). The same material also carries (a–d).

Worked problem
“the raw material used as input and the processed data obtained as output of data processing”

Data, Instructions — option (a): data is the raw material; processing it yields the desired output in the form of instructions (an ordered set of which is a program).

2Processor organization — single-bus datapath

Inside the processor, the registers, ALU and interconnecting bus are collectively called the data path. In the single-bus organization only one data item can be transferred over the bus in a clock cycle, so operations need several control steps.

Internal processor busPCMARMDRYMUXZAddress linesData linesALUASelect4 / SelectYConstant 4BInstruction decoder& control logicIRR0 R1 … Rn−1TEMPB input comes straightfrom the bus
Single-bus organization of the datapath (redraw the register boxes, the bus, ALU with MUX and the Y/Z/TEMP registers)
MFC = Memory-Function-Completed — the memory’s “I am done” reply. The processor waits for it (WMFC) because response times vary (cache miss, memory-mapped I/O…).
Worked problem
“Explain the processor organization with neat diagram”

Draw the figure above, then explain every register block in the same order as the bullets, finish with “data path = registers + ALU + interconnecting bus” and the MFC note.

Worked problem
MAR stands for?

Memory Address Register — option (d).

Data path — option (a).

3Register transfers & gating

Every register’s connection to the bus is controlled by two signals: Ri_in and Ri_out. All transfers happen inside time periods defined by the processor clock.

processor busMUX2 × 1 MUXRi_indata on the busDQClockQtri-state gateRi_outRi_out = 1 → gate drives the busRi_out = 0 → high impedance (open switch)Ri_in = 1 → MUX passes the bus data · Ri_in = 0 → MUX feeds Q back (bit re-stored every cycle)
Input/output gating for one register bit — 2×1 MUX + edge-triggered D flip-flop + tri-state gate; Q is fed back to the MUX so the bit is re-stored when Ri_in = 0

Example — transfer the contents of R1 to R4 (a favourite 2-mark sequence):

StepSignal(s)What happens
1R1_out = 1contents of R1 placed on the bus
2R4_in = 1bus data loaded into R4

Because both actions need the bus in the same step and only the input latch waits for the clock edge, R1_out and R4_in can be asserted in the same clock cycle — the transfer completes in one step.

Worked problem
“Register Transfers”

Define Ri_in / Ri_out, draw the register-bit gating figure, mention tri-state high-impedance, edge-triggered D flip-flop behaviour (Ri_in = 0 → feedback) and multiphase clocking. Close with the R1 → R4 two-signal example.

4Performing an ALU operation

The ALU is combinational — no internal storage. Its two operands must be present simultaneously, but the single bus carries only one word per cycle, so one operand is parked in register Y and the result in register Z.

Add the contents of R1 to R2 and store the result in R3  ([R3] ← [R1] + [R2]):
Step 1 — R1_out, Y_in   (bus carries R1 → latched into Y)
Step 2 — R2_out, SelectY, Add, Z_in   (A = [Y] = R1, B = R2 from bus → Z)
Step 3 — Z_out, R3_in   (result moves from Z to the destination)

Why three steps? In step 2 the bus is busy carrying R2, so R1 must already sit in Y; and the ALU output cannot go straight onto the bus that is still carrying R2 — hence the temporary Z. The multiplexer’s SelectY signal routes Y to input A; Select4 would instead route the constant 4 (used to increment the PC).

Worked problem
“Performing an ALU operation”

State the no-internal-storage fact → the role of Y (operand staging) and Z (result holding) → write the 3-step signal sequence exactly as in the keybox → explain why each step is needed.

5Fetching & storing a word from memory

Memory access is asynchronous — response time varies (cache miss, memory-mapped I/O). The processor therefore issues the request and waits for MFC (WMFC) before continuing.

Read: Move (R1), R2  — [R2] ← [[R1]]
Step 1 — R1_out, MAR_in, Read  (address out, read request issued)
Step 2 — MDR_inE, WMFC  (wait for MFC; MDR_inE enables external data into MDR)
Step 3 — MDR_out, R2_in  (data to destination)
Time1234Addressaddress of location valid on address linesReadRead request issuedMFCMemory-Function-CompletedDataMDR loads the data1 address+Read → 2 wait (WMFC) → 3 MFC received → 4 data in MDR
Timing of a memory read — address + Read go out together, the processor waits (WMFC) until MFC, then MDR loads the data

MDR’s connection to the outside world needs special care: it sits between the internal bus and the external memory-data lines, so tri-state gates controlled by MDR_inE / MDR_outE decide which side drives it.

Write: Move R2, (R1)  — [[R1]] ← [R2]
Step 1 — R1_out, MAR_in  (address out)
Step 2 — R2_out, MDR_in, Write  (data out, write request issued)
Step 3 — MDR_outE, WMFC  (wait for the memory to complete)

Note the read/write asymmetry: a write keeps the data stable on the data lines until the memory completes, whereas a read loads MDR when MFC arrives. Both end with WMFC — the only step that can stretch over many clock cycles.

Worked problem
“Fetching / Storing a word from memory”

For (c): the Move (R1), R2 sequence + timing diagram + MFC/WMFC meaning + MDR connection figure. For (d): the Move R2, (R1) sequence; point out address → data → Write order and the final WMFC.

6Execution of a complete instruction

Putting everything together: Add (R3), R1 — add the contents of the memory location pointed to by R3 into R1. The fetch phase is common to every instruction; the execution phase depends on the opcode.

StepControl signalsAction
1PC_out, MAR_in, Read, Select4, Add, Z_infetch begins; Z ← [PC] + 4
2Z_out, PC_in, WMFCPC updated; wait for memory
3MDR_out, IR_ininstruction loaded into IR
4R3_out, MAR_in, Readoperand address out; read starts
5R1_out, Y_in, WMFCR1 staged in Y; wait for MFC
6MDR_out, SelectY, Add, Z_inZ ← [R1] + [memory operand]
7Z_out, R1_in, Endresult into R1; fetch next instruction

The End signal resets the control-step counter so the next fetch cycle starts immediately. Steps 1–3 are the fetch phase; steps 4–7 the execution phase.

Branch instructions. A branch replaces PC with the branch target address = (address following the branch) + offset X. Unconditional-branch sequence:
1 — PC_out, MAR_in, Read, Select4, Add, Z_in
2 — Z_out, PC_in, WMFC
3 — MDR_out, IR_in
4 — Offset-field-of-IR_out, SelectY, Add, Z_in
5 — Z_out, PC_in, End

In step 4 the sign-extended offset comes from the IR over the bus (ALU input B) while SelectY feeds input A; the sum is the target address, which step 5 loads into the PC. A conditional branch tests the condition-code flags first and updates the PC only if the condition holds.

Worked problem
“Instruction execution in a processor”

The 7-step table above is the heart of the answer — practise writing it until automatic. The same table reappears as the worked example inside the hardwired-control answer (§8).

7Multi-bus organization

The single bus forces long control sequences (one transfer per cycle). Most commercial processors therefore provide multiple internal paths so that several transfers happen in parallel — fewer control steps per instruction.

Single-bus structureMulti-bus structure
Pathsone common busseveral internal buses (e.g. A, B, C)
Transfers / cycleone data itemmultiple, in parallel
Control sequencelongshort
Hardware costlowmore (extra ports, buses)
Bus ABus BBus CRegisterfileRAout, RBout(two output ports)Rin (input port)ABALUresultIncrementerunitPC + 4PCIRNo registers Y and Z needed — the three buses let sources meet the ALUand the destination receive the result in one clock cycle.
Three-bus organization — register file with two output ports (A, B) and one input port (C); the incrementer unit updates the PC by 4
StepActionRemarks
1PC_out, R=B, MAR_in, Read, IncPCPC passes through ALU (R=B) into MAR; PC incremented
2WMFCwait for Memory-Function-Complete
3MDR_outB, R=B, IR_ininstruction from MDR (bus B) through ALU into IR
4R4_outA, R5_outB, SelectA, Add, R6_in, EndR4, R5 out on buses A, B; sum over bus C into R6 — done in one cycle
Worked problem
“Multibus organization”

Give the single- vs multi-bus comparison table → the three-bus figure with the register-file ports → the Add R4,R5,R6 step table → note the disappearance of Y/Z and the role of the incrementer unit.

8Hardwired control

The control unit must generate the control signals in proper sequence. In a hardwired unit they are produced by combinational circuitry — the control unit is designed as a finite state machine. Inflexible but fast — appropriate for simpler machines (RISC).

Control step counterDecoder /Encoder(combinational —“fixed logic”)ClockRUNIRopcodeConditioncodesExternalinputs (MFC)which step T₁…TₖEND — resets the counter: new fetch cycle beginscontrol signals (R1out, Yin, Add, Zin, Read, …)One clock cycle = one control step · RUN = 0 freezes the counter (during WMFC)
Hardwired control unit — the decoder/encoder (fixed logic) combines the step count, opcode, condition codes and external inputs into control signals

The required control signals are determined by four pieces of information:

The decoder/encoder block is a combinational circuit that turns these inputs into the control outputs. Two more signals manage the counter itself:

RUN — when set to 0 the counter holds its value irrespective of the clock (done while WMFC is issued).
END — resets the step counter to its starting value, beginning a new instruction fetch cycle.

Example logic. Looking at where Z_in is asserted in the Add (R3),R1 and Branch sequences (steps T1, T6 of ADD; T4 of BR):

Z_in = T1 + T6·ADD + T4·Br + …
END = T7·ADD + T5·BR + (T4·N′ + T5·N)·BRN + …  (N′ = N complemented)

Each new instruction simply ORs its own terms into the equations — that is also exactly why the design is called inflexible: the logic must be rewired when the instruction set changes. The simplest implementation method is the state-table method; the sequence-counter method is the most widely used.

Worked problem
“Explain the hardwired control unit with necessary block diagram”

Draw the block diagram → list the four input groups → explain counter/RUN/END → derive the two example equations → close with the hardwired-vs-microprogrammed table from §9. Also serves.

control-unit MCQs —

• the microprogrammed control unit is the flexible one (b). • combinational-logic signal generation = hardwired (d). • simplest method of implementing a hardwired unit = State Table Method (a) — note the sequence-counter method is only the most popular.

9Microprogrammed control

Here the control signals are generated by a micro-program — a sequence of 0s and 1s stored like machine-language code. If PC_out is needed in a step, the bit allocated to PC_out in that word is set to 1. Flexible but slow — appropriate for complex machines (CISC).

IRStarting & branchaddress generatorCondition codes,external inputsµPCµPC ← start / branchControl store(holds all CWs)µPC = addressCW→ control signalsbranch address bits of CWClockincrements µPCSuccessive microinstructions are readsequentially — one per clock pulse.µPC is NOT incremented when:new IR · branch taken · End
Microprogrammed control unit — the µPC addresses the control store; the starting & branch address generator loads it on IR events and taken branches
The µPC is not incremented (i.e. it is loaded instead) when:
1 · a new instruction is loaded into IR → starting address of its microroutine
2 · a branch microinstruction is encountered and its condition is satisfied → branch address
3 · an End microinstruction is encountered → address of the first CW of the instruction-fetch microroutine
Hardwired vs microprogrammed:
circuitry producing signals vs microprogram of 0s/1s · finite-state machine vs hierarchical design like a CPU · fast, inflexible (RISC) vs flexible, slow (CISC) · easier to change = just rewrite the control store.
Worked problem
“Basic organization of microprogrammed control unit and branching in microinstructions”

Define CW / microinstruction / microroutine / control store → draw the block diagram (IR → generator → µPC → control store → CW, with the branch-address feedback) → explain the three µPC-loading cases → walk through the Branch-N microroutine listing of §10. is answered by the comparison keybox (with §8).

Worked problem
which control unit is flexible?

Microprogrammed control unit — option (b).

10Control word format — shrinking microinstructions

The naive approach — one bit per control signal — produces very long microinstructions, because there are many signals yet only a few are 1 in any given step (poor bit-space use). The fix: exploit that most signals are mutually exclusive.

Encoding: group mutually exclusive signals into the same field; at most one micro-operation per field, binary-coded. Examples: a 16-operation ALU needs only 4 bits; PC_out, MDR_out, Z_out, Offset_out, R0_out … Temp_out (9 register-output signals) share one group and again fit in 4 bits. Most fields also keep one inactive code meaning “no action”. This is the vertical style; the one-bit-per- signal extreme is the horizontal style (faster, longer words).

1PC_out1MAR_in1Read0Select40SelectY0Add0Sub0Z_in0End……One control word — one clock step of the fetch phase:PC_out = MAR_in = Read = 1, everything else 0a microroutine = the full sequence of CWs for one instruction
A control word for the fetch step — one bit field per signal; here PC_out = MAR_in = Read = 1
AddrMicroroutine of Branch N (sample listing)
0PC_out, MAR_in, Read, Select4, Add, Z_in
1Z_out, PC_in, WMFC
2MDR_out, IR_in
3branch to starting address of the appropriate microroutine
25If N = 0 then branch to microinstruction 0
26Offset-field-of-IR_out, SelectY, Add, Z_in
27Z_out, PC_in, End

The listing shows the conditional jump from address 25 back to 0 when N = 0: the branch is simply not taken by the machine. The target address of such conditional jumps is produced by the starting & branch address generator (which now also receives the condition codes and external inputs).

Worked problem
follow-through

After the block diagram (§9), add: the grouping/encoding idea with both examples, the sample Branch-N listing, and the remark that the generator produces conditional-jump target addresses.

11Pipelining — basic concepts

Two ways to make a processor faster: faster circuit technology, or arrange the hardware so that more than one operation is performed at the same time. Pipelining is the second idea: like an assembly line, the execution of the current instruction overlaps the execution of subsequent ones — instruction-level parallelism.

Fetch unit(F)intermediatebuffer B1Execute unit(E)clockWhile I₂ is fetched, I₁ is executed — the two units never idle.
Two-stage pipeline — a fetch unit, an execution unit and one intermediate buffer
Clock cycle →12345
Fetch unitI1I2I3I4I5
Execute unit—I1I2I3I4

By the end of cycle 2 both units are busy — and they stay busy. With four stages each instruction passes through four dedicated hardware units, buffers B1–B3 between them:

F Fetch the instruction · D Decode it · E Execute · W Write the result to its destination
Fetch(F)B1Decode(D)B2Execute(E)B3Write(W)clockFour dedicated hardware units + three buffers — a new instruction can enter every cycle.
Hardware organization of a 4-stage pipeline — four units, three buffers
Instruction ↓ / cycle →1234567
I1FDEW
I2FDEW
I3FDEW
I4FDEW

Every stage is controlled by one clock cycle; a new instruction enters the pipe each cycle and one finishes each cycle (once full). The role of cache memory: each stage must complete in one clock period, but main-memory access is far slower — so a cache is added, and if it sits on the processor chip its access time matches the pipeline stage time.

Worked problem
“Basic concepts of pipelining / how pipelining improves instruction throughput”

Definition + assembly-line analogy → 2-stage hardware & timeline → 4-stage hardware, F/D/E/W and the timeline → throughput argument (§12) → mention cache. All three Part-B questions share this one answer.

pipelining MCQs —

• the term for simultaneous access to a resource (physical or logical) is Concurrency (d). • pipelining is also called the Assembly-line operation (b).

12Pipeline performance — and why it stalls

Pipelining increases the instruction throughput — the number of instructions completed per unit time — so the program runs faster and its total execution time falls, without making any single instruction faster.

k stages, n instructions, stage time τ:
sequential time = n·k·τ   ·   pipelined time = (k + n − 1)·τ
Speedup S = n·k / (k + n − 1) → approaches k for large n.  In a 4-stage pipeline the completion rate is up to 4× sequential — increase is proportional to the number of stages — but only while the pipe keeps flowing.

Real pipelines stall. A cache miss in a fetch freezes everything behind it:

Clock cycle →1234567
F (I1)F1
F (I2)F2 (miss — wait)F2F2
D——D1D2
E——E1E2
W——W1

The same happens when one stage simply needs more cycles — e.g. I2 takes 3 cycles in its execute stage (cycles 4, 5, 6): in cycles 5 and 6 the write stage must be told to do nothing, because it has no data to work with.

Worked problem
“how pipelining improves instruction throughput” · PART A

Define throughput → give the S = nk/(k+n−1) derivation and the “proportional to stages” remark → then honestly note the interruptions (cache miss, unequal stage length) that bring us to hazards (§13–§14).: to increase memory-access speed in pipelining we use Cache (c).

13Pipeline hazards — structural & data

A hazard is any situation that prevents the next instruction in the stream from executing during its designated clock cycle. Hazards are the major hurdle of pipelining — they drag performance below the ideal speed-up and make stalls necessary. Three classes: structural, data, control/instruction.

1 · Structural hazards — resource conflicts: the hardware cannot support all possible combinations of instructions in overlapped execution.
2 · Data hazards — an instruction depends on the result of a previous one.
3 · Control / instruction hazards — branches and other PC-changing instructions (or a cache miss that leaves the fetch stream empty).

Structural example: if one memory pipeline serves both data and instructions, an instruction containing a data-memory reference conflicts with the instruction fetch of a later instruction. Remedy: stall one clock cycle when the data access occurs — the inserted idle period is called a pipeline bubble. Stalls push the CPI above its ideal value of 1 (example: Load x(R1), R2 with unified memory).

Data example:

  ADD R2, R3, R1     ; writes R1
  SUB R4, R1, R5     ; reads R1 — too early!

The ADD writes R1 in its WB stage, but SUB reaches its ID stage before that write happens — this is the classic data hazard. Its three types (asked by name in Part C):

TypeAlso calledPattern
RAWtrue / flow dependencewrite…then read — the ADD/SUB case above
WAWoutput dependencetwo instructions write the same register
WARanti-dependencea later instruction writes a register an earlier one still reads
ADD R2,R3,R1FDEWSUB R4,R1,R5FDEWforwarding (bypass)The ADD result is forwarded straight into SUB's Execute stage — no stall needed.After a Load, though, data is available only after memory — one stall is unavoidable.
Minimizing data-hazard stalls by forwarding (bypassing / short-circuiting)

Forwarding routes the ALU result of ADD straight into SUB’s Execute stage instead of waiting for it to be written back. It cannot always help: after

  LD  0(R2), R1     ; R1 ← memory
  DSUB R4, R1, R5   ; needs R1 — 1 stall even with forwarding
  AND  R6, R1, R7   ; satisfied by forwarding
  OR   R8, R1, R9   ; satisfied by forwarding
MEM
Worked problem
“structural hazards and data hazards” · PART C

B6: define hazard → three classes with the structural memory-conflict example and the ADD/ SUB data example + forwarding. C1: name RAW / WAW / WAR with one-line causes, then the LD/DSUB/ AND/OR stall sequence. C2: performance gain (§12) + the three hazard classes as the hurdles.

14Instruction (control) hazards — branches & prefetch

Whenever the stream of instructions supplied by the fetch unit is interrupted, the pipeline stalls. Branches are the usual culprit: the processor does not know where to fetch next until the branch resolves.

Instruction queue & prefetching. To soften cache misses and branches, the fetch unit fetches instructions ahead of time into a queue and keeps it filled at all times. The dispatch unit takes instructions from the front of the queue, performs the decoding operation and sends them to the execution units. If fetching is delayed, the dispatch unit keeps issuing from the queue.
Fetch unit(keeps queue full)I4I3I2I1instruction queue (FIFO)Dispatch unitdecodes + issues→ execution unitsA cache miss or branch stalls the fetch unit — the dispatch unit keeps issuing from the queue.
Instruction queue and prefetching — fetch feeds the FIFO; the dispatch unit decodes and issues
Worked problem
“Organize the branching instruction in pipelining” (first half)

Instruction hazards → the 2-stage branch/flush story → branch penalty & how to reduce it → instruction queue / dispatch unit (this figure) → then continue with delayed branch and prediction in §15 for the second half of the answer.

15Delayed branch & branch prediction

A conditional branch adds a further hazard: the branch condition may depend on the result of a preceding instruction, so the decision cannot be made until that instruction finishes executing.

Delayed branch. The location following the branch is the branch delay slot. Its instruction is fetched anyway, so we would like it to be fully executed whether or not the branch is taken — the objective is to place useful instructions in the slot. Success depends on how often the compiler can reorder instructions:

(a) no useful instruction(b) from the target(c) from before the branch
branch — delay slot filled with NOPtarget instruction moved up into the slotinstruction preceding the branch moved into the slot (if legal)

Branch prediction. The simplest form: assume not taken and keep fetching in sequential address order. Until the branch is evaluated, execution along the predicted path is done on a speculative basis — instructions are executed before the processor is certain they are in the correct sequence, so no registers or memory locations may be updated until confirmation. An incorrect prediction means discarding the speculative work and fetching the correct path.

LTLNTBTBNTBNTBTpredict takenpredict not takentaken → go to (or stay in) LT not taken → go to (or stay in) LNT2-state algorithm — decision depends only on the most recent outcome
2-state algorithm — LT (predict taken) / LNT (predict not taken); the move depends only on the most recent outcome
2-state rule: taken → go to (or stay in) LT; not taken → go to (or stay in) LNT. Predict taken iff the machine is in LT.
LNTSNTLTSTpredict takenpredict not takenBTBNTBTBNTBTBNTBTBNT
4-state algorithm — ST / LT predict taken (green), LNT / SNT predict not taken (red); start in LNT
4-state rule: start in LNT. Branch taken → move one step toward ST; not taken → one step toward SNT. The fetch unit predicts taken iff the state is LT or ST (and then begins fetching at the branch target address); otherwise it continues sequentially. In SNT a taken branch is a wrong prediction → the state becomes LNT.
Worked problem
“branch prediction algorithm with static and dynamic prediction”

Delay slot + the three filling strategies → speculative execution → static vs dynamic → draw both state diagrams and state their rules. (Slide wording “if taken it changes to ST” means it moves one step toward ST: LNT → LT → ST.)

16Influence on instruction sets

Some instructions are much better suited to pipelined execution than others. The two big design questions are the addressing modes and the condition-code flags.

Addressing modes. In choosing modes for a pipelined processor, weigh each mode’s effect on instruction flow: (1) its side effects, (2) how far the mode makes the pipeline stall, (3) how likely compilers are to use it. Complex modes save instruction count — Load (X(R1)), R2 needs an extra memory access and stalls the pipe — while the simple equivalent pair Add #X, R1, R2 / Load (R2), R2 flows smoothly. Complex modes are therefore not suitable for pipelined execution: their advantage (fewer instructions / program space) is outweighed by stalls, extra decoding hardware and compiler inconvenience.

Good addressing modes for a pipelined processor:
· access to an operand requires no more than one memory access
· only Load and Store instructions access memory operands
· the modes have no side effects
→ use register, register-indirect and index modes.

Conditional codes. An optimizing compiler reorders instructions to hide stalls, but must not change the outcome of the computation — and the dependency introduced by condition-code flags reduces that reordering flexibility. Two conclusions:

this topic is not asked directly, but Quote the “good addressing modes” keybox and the condition-code conclusions when you finish a Part-B Q9 or Part-C Q2 answer — examiners reward the “influence on instruction sets” wrap-up.